Hladnjak sušača za komprimirani zrakCORMAK
Izberg N30S
Hladnjak sušača za komprimirani zrak
CORMAK
Izberg N30S
fiksna cijena plus PDV
1.009 €
godina proizvodnje
2025
Stanje
Novi
Lokacija
Siedlce 

Slike prikazuju
Prikaži kartu
Podaci o mašini
- Naziv mašine:
- Hladnjak sušača za komprimirani zrak
- proizvođač:
- CORMAK
- Model:
- Izberg N30S
- godina proizvodnje:
- 2025
- Stanje:
- novo
- funkcionalnost:
- potpuno funkcionalan
Cijena i lokacija
fiksna cijena plus PDV
1.009 €
- Lokacija:
- Brzeska 120, 08-110 Siedlce, PL
Pozovite
Detalji ponude
- ID oglasa:
- A11000909
- ažuriranje:
- posljednji put 07.07.2025
Opis
The purpose of a compressed air refrigerant dryer is to lower the temperature of the compressed air and remove water and oil particles contained in the air flow. Refrigerant dryers are important in applications where moist air could cause corrosion, contamination or damage to tools, machinery or products. By removing moisture, the dryer increases the reliability and durability of compressed air systems.
The refrigerant dryer is designed for maximum efficiency and durability. The main design elements include:
1. Air-to-air heat exchanger
In the first stage of the process, the inlet air passes through a heat exchanger, where it is pre-cooled by the cooler air leaving the evaporator. By using countercurrent flow, heat recovery increases the energy efficiency of the entire system.
Hodpfx Aasmt Dcqs Renu
2. Refrigeration system evaporator
In the second stage, the compressed air is fed to the evaporator, where it is cooled to a dew point temperature of 3°C. This results in the condensation of water vapor and oil particles contained in it. 3. Condensate separator
After cooling, the gas and condensate mixture goes to an efficient separator, where the condensate is separated and automatically drained outside the device.
4. Fan control system
The variable speed fan technology allows intelligent adjustment of the cooling intensity to the actual demand, which reduces energy consumption and increases the service life of the components.
Technical parameters
Inlet/outlet pipe diameter (BSP) 1 1/2"
Maximum operating pressure 10 bar
Maximum inlet air temperature ≤ 38°C
Dew point temperature 3°C
Efficiency 3800 l/min
Power 0.9 kW
Supply voltage 230 V
Dimensions (L x W x H) 850 x 480 x 480 mm
Weight 95 kg
Type and amount of refrigerant R410a, 650 g
The refrigerant dryer is designed for maximum efficiency and durability. The main design elements include:
1. Air-to-air heat exchanger
In the first stage of the process, the inlet air passes through a heat exchanger, where it is pre-cooled by the cooler air leaving the evaporator. By using countercurrent flow, heat recovery increases the energy efficiency of the entire system.
Hodpfx Aasmt Dcqs Renu
2. Refrigeration system evaporator
In the second stage, the compressed air is fed to the evaporator, where it is cooled to a dew point temperature of 3°C. This results in the condensation of water vapor and oil particles contained in it. 3. Condensate separator
After cooling, the gas and condensate mixture goes to an efficient separator, where the condensate is separated and automatically drained outside the device.
4. Fan control system
The variable speed fan technology allows intelligent adjustment of the cooling intensity to the actual demand, which reduces energy consumption and increases the service life of the components.
Technical parameters
Inlet/outlet pipe diameter (BSP) 1 1/2"
Maximum operating pressure 10 bar
Maximum inlet air temperature ≤ 38°C
Dew point temperature 3°C
Efficiency 3800 l/min
Power 0.9 kW
Supply voltage 230 V
Dimensions (L x W x H) 850 x 480 x 480 mm
Weight 95 kg
Type and amount of refrigerant R410a, 650 g
Dobavljač
Napomena: Registrujte se besplatno ili prijavite, za pristup svim informacijama.
Pošaljite upit
Telefon & Faks
+48 25 63... oglasi
Vaš oglas je uspješno izbrisan
Došlo je do greške