CTS CW‑60/11 – Water-Cooled Climatic Test Chamber
The CW‑60/6 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in or drive-in climatic chamber designed for temperature and humidity testing of multiple specimens simultaneously.
Device Description
The climatic test chamber allows the function or material properties of a sample to be tested under the influence of temperature and humidity. Efficient air circulation with a correspondingly high recirculation volume ensures effective heat transfer to the test samples. The air handling unit is located at the rear of the interior chamber. The refrigeration units are mounted in a separate frame behind the device, providing easy access. The control system is housed in a separate control cabinet, with the control panel integrated into the cabinet door. For dehumidification of the test chamber, the unit is equipped with a self-regenerating compressed-air dryer. Fresh air flushing of the chamber is possible via a dedicated fan.
Technical Performance Data:
Temperature Tests:
Temperature range: –60 °C to +90 °C
Temperature deviation (temporal): ±0.5 to 1 K
Temperature deviation (spatial): ±1 K at 200 mm distance from the wall
Temperature change rate (supply air, linear):
Heating: 2 K/min from –40 °C to +85 °C
Cooling: 2 K/min from +85 °C to –40 °C
Climatic Tests
Temperature range: +10 °C to +95 °C
Humidity range: 10% to 95% RH
Dew point range: +5 °C to +89 °C
Temperature deviation (temporal): ±0.5 K
Humidity deviation: ±2 – ±5% RH (temporal)
No radiant heat
In steady-state condition
Technical data refer to ambient temperature +25 °C, nominal voltage 400 V, without test sample, without radiant heat and without additional equipment.
Dimensions:
Internal dimensions (test space / usable volume):
Volume: approx. 11,000 liters (11 m³)
Internal dimensions (approx.): Height: 2500 mm, Width: 2200-2250 mm, Depth: 2400-2500 mm (may vary slightly depending on configuration)
External dimensions: Height: 2900 mm, Width: 2380 mm, Depth: 2890 mm (depending on door, frame, accessories, etc.)
Operating Data:
Nominal power: 84.4 kW
Nominal voltage: 400 V 3/N 50 Hz
Nominal current: 131.4 A
Technical Specifications:
Refrigeration unit: Water-cooled, low-noise, semi-hermetic, stepless power adjustment via electronic monitoring and control system, environmentally-friendly refrigerants R 23 / R 404 A
Notes
Inspection by appointment only (46325 Borken)
Tsdpfx Ajx Ankyod Hof
Shipping by freight forwarder possible – Costs & arrangements upon request
Scope of delivery: (see images)
(Specifications and technical data subject to change and error!)
For further questions, we are happy to assist you by phone.
Oglas je automatski preveden. Moguće su greške u prijevodu.
The CW‑60/6 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in or drive-in climatic chamber designed for temperature and humidity testing of multiple specimens simultaneously.
Device Description
The climatic test chamber allows the function or material properties of a sample to be tested under the influence of temperature and humidity. Efficient air circulation with a correspondingly high recirculation volume ensures effective heat transfer to the test samples. The air handling unit is located at the rear of the interior chamber. The refrigeration units are mounted in a separate frame behind the device, providing easy access. The control system is housed in a separate control cabinet, with the control panel integrated into the cabinet door. For dehumidification of the test chamber, the unit is equipped with a self-regenerating compressed-air dryer. Fresh air flushing of the chamber is possible via a dedicated fan.
Technical Performance Data:
Temperature Tests:
Temperature range: –60 °C to +90 °C
Temperature deviation (temporal): ±0.5 to 1 K
Temperature deviation (spatial): ±1 K at 200 mm distance from the wall
Temperature change rate (supply air, linear):
Heating: 2 K/min from –40 °C to +85 °C
Cooling: 2 K/min from +85 °C to –40 °C
Climatic Tests
Temperature range: +10 °C to +95 °C
Humidity range: 10% to 95% RH
Dew point range: +5 °C to +89 °C
Temperature deviation (temporal): ±0.5 K
Humidity deviation: ±2 – ±5% RH (temporal)
No radiant heat
In steady-state condition
Technical data refer to ambient temperature +25 °C, nominal voltage 400 V, without test sample, without radiant heat and without additional equipment.
Dimensions:
Internal dimensions (test space / usable volume):
Volume: approx. 11,000 liters (11 m³)
Internal dimensions (approx.): Height: 2500 mm, Width: 2200-2250 mm, Depth: 2400-2500 mm (may vary slightly depending on configuration)
External dimensions: Height: 2900 mm, Width: 2380 mm, Depth: 2890 mm (depending on door, frame, accessories, etc.)
Operating Data:
Nominal power: 84.4 kW
Nominal voltage: 400 V 3/N 50 Hz
Nominal current: 131.4 A
Technical Specifications:
Refrigeration unit: Water-cooled, low-noise, semi-hermetic, stepless power adjustment via electronic monitoring and control system, environmentally-friendly refrigerants R 23 / R 404 A
Notes
Inspection by appointment only (46325 Borken)
Tsdpfx Ajx Ankyod Hof
Shipping by freight forwarder possible – Costs & arrangements upon request
Scope of delivery: (see images)
(Specifications and technical data subject to change and error!)
For further questions, we are happy to assist you by phone.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Dobavljač
Napomena: Registrujte se besplatno ili prijavite, za pristup svim informacijama.
Registriran od: 2012
Pošaljite upit
Telefon & Faks
+49 2861 ... oglasi
Ovi oglasi bi vas također mogli zanimati.
mali oglas
Borken
1.194 km
Klimatska testna komora kapaciteta 11.000 litara (11 m³)
CTSCW-60/11 -60°C bis +90°C
CTSCW-60/11 -60°C bis +90°C
Vaš oglas je uspješno izbrisan
Došlo je do greške