EA Elektro-Automatik laboratorijsko napajanje EA-EL 9080-170 BEA
Labornetzteil EL 9080
EA Elektro-Automatik laboratorijsko napajanje EA-EL 9080-170 B
EA
Labornetzteil EL 9080
VB plus PDV
3.300 €
Stanje
Polovno
Lokacija
Borken 

Osnovni podaci
Cijena i lokacija
VB plus PDV
3.300 €
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Pozovite
Detalji ponude
- ID oglasa:
- A17359363
- Referentni broj:
- 24358
- Ažuriranje:
- posljednji put 15.10.2026
Opis
EA Elektro Automatik
Type: EA-EL 9080-170 B
Electronic DC load, USB / Analog / Master-Slave, Programmable, 80V, 170A, 2.4kW
Technical data:
Mains voltage 90...264 V AC
Mains connection type Socket
Mains frequency 45...65 Hz
Mains fuse T 6.3
Power consumption Max. 90 W
Leakage current < 3.5 mA
DC input
Input voltage 80 V
Input power 2400 W
Input current 170 A
Overvoltage protection range 0...1.03 * UNom
Overcurrent protection range 0...1.1 * INom
Overpower protection range 0...1.1 * PMax
Gusdouv Eudspfx Af Tsh
Maximum permissible input voltage 88 V
Min. input voltage for IMax Approx. 2.2 V
Temperature coefficient of the setpoint values Δ / K Current / Voltage: 30 ppm
Voltage regulation
Setting range 0...81.6 V
Stability at ΔI < 0.05%
Accuracy (at 23 ± 5°C) ≤ 0.1% UNom
Display: Accuracy ≤ 0.1% UNom
Remote sensing compensation Max. 5% UNom
Current regulation
Setting range 0...173.4 A
Stability at ΔU < 0.1% INom
Accuracy (at 23 ± 5°C) ≤ 0.2% INom
Display: Accuracy ≤ 0.1% INom
Rise time 10...90% INom < 23 μs
Fall time 90...10% INom < 46 μs
Power regulation
Setting range 0…2428 W
Accuracy (at 23 ± 5°C) < 0.5% PMax
Display: Accuracy ≤ 0.2% PMax
Resistance regulation
Setting range 0.04…15.3 Ω
Accuracy (at 23 ± 5°C) ≤ 1% of the resistance end value + 0.3% of INom
Display: Accuracy Included in the accuracy of the setpoint value
EL 9080-170 B:
Analog interface:
Setpoint inputs U, I, P, R
Actual value outputs U, I
Control signals DC on/off, Remote control on/off, R-mode on/off
Status signals CV, OVP, OCP, OPP, OT, PF, DC on/off
Galvanic isolation to the device Max. 400 V DC
Sampling rate Setpoint inputs 500 Hz
Isolation:
Input (DC) to housing DC-minus: permanently max. ±400 V
DC-Plus: permanently max. ±400 V + max. input voltage
Input (AC) to Input (DC) Max. 2500 V, briefly
Climate:
Cooling method Temperature-controlled fan
Ambient temperature 0...50 °C
Storage temperature -20...70 °C
Digital interfaces
Built-in 1x USB-B for communication, 1x USB-A for functions, 1x Master-Slave bus
Slot for digital modules Optional: CAN, CANopen, Profibus, Profinet, RS232, Ethernet, ModBus TCP, EtherCAT
Galvanic isolation to the device Max. 400 V DC
Connections:
Rear Share-Bus, DC input, AC input, Sense, Analog interface, USB-B, Master-Slave bus, Interface module slot
Front USB-A
Dimensions:
Housing (W x H x D) 19" x 2 U x 464 mm
Total (W x H x D) 483 mm x 88 mm x 538 mm
Standards EN 61010-1:2007-11, EN 61000-6-2:2005, EN 61000-6-3:2006 Class B
Weight ≈ 11 kg
Documents & Downloads
Datasheet: Operating manual
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Type: EA-EL 9080-170 B
Electronic DC load, USB / Analog / Master-Slave, Programmable, 80V, 170A, 2.4kW
Technical data:
Mains voltage 90...264 V AC
Mains connection type Socket
Mains frequency 45...65 Hz
Mains fuse T 6.3
Power consumption Max. 90 W
Leakage current < 3.5 mA
DC input
Input voltage 80 V
Input power 2400 W
Input current 170 A
Overvoltage protection range 0...1.03 * UNom
Overcurrent protection range 0...1.1 * INom
Overpower protection range 0...1.1 * PMax
Gusdouv Eudspfx Af Tsh
Maximum permissible input voltage 88 V
Min. input voltage for IMax Approx. 2.2 V
Temperature coefficient of the setpoint values Δ / K Current / Voltage: 30 ppm
Voltage regulation
Setting range 0...81.6 V
Stability at ΔI < 0.05%
Accuracy (at 23 ± 5°C) ≤ 0.1% UNom
Display: Accuracy ≤ 0.1% UNom
Remote sensing compensation Max. 5% UNom
Current regulation
Setting range 0...173.4 A
Stability at ΔU < 0.1% INom
Accuracy (at 23 ± 5°C) ≤ 0.2% INom
Display: Accuracy ≤ 0.1% INom
Rise time 10...90% INom < 23 μs
Fall time 90...10% INom < 46 μs
Power regulation
Setting range 0…2428 W
Accuracy (at 23 ± 5°C) < 0.5% PMax
Display: Accuracy ≤ 0.2% PMax
Resistance regulation
Setting range 0.04…15.3 Ω
Accuracy (at 23 ± 5°C) ≤ 1% of the resistance end value + 0.3% of INom
Display: Accuracy Included in the accuracy of the setpoint value
EL 9080-170 B:
Analog interface:
Setpoint inputs U, I, P, R
Actual value outputs U, I
Control signals DC on/off, Remote control on/off, R-mode on/off
Status signals CV, OVP, OCP, OPP, OT, PF, DC on/off
Galvanic isolation to the device Max. 400 V DC
Sampling rate Setpoint inputs 500 Hz
Isolation:
Input (DC) to housing DC-minus: permanently max. ±400 V
DC-Plus: permanently max. ±400 V + max. input voltage
Input (AC) to Input (DC) Max. 2500 V, briefly
Climate:
Cooling method Temperature-controlled fan
Ambient temperature 0...50 °C
Storage temperature -20...70 °C
Digital interfaces
Built-in 1x USB-B for communication, 1x USB-A for functions, 1x Master-Slave bus
Slot for digital modules Optional: CAN, CANopen, Profibus, Profinet, RS232, Ethernet, ModBus TCP, EtherCAT
Galvanic isolation to the device Max. 400 V DC
Connections:
Rear Share-Bus, DC input, AC input, Sense, Analog interface, USB-B, Master-Slave bus, Interface module slot
Front USB-A
Dimensions:
Housing (W x H x D) 19" x 2 U x 464 mm
Total (W x H x D) 483 mm x 88 mm x 538 mm
Standards EN 61010-1:2007-11, EN 61000-6-2:2005, EN 61000-6-3:2006 Class B
Weight ≈ 11 kg
Documents & Downloads
Datasheet: Operating manual
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Pošaljite upit
Telefon & Faks
+49 2861 ... oglasi
Vaš oglas je uspješno izbrisan
Došlo je do greške