STATIČKI AUTOKLAV OD NEHRĐAVAJUĆEG ČELJA LAGARDE 4 BLagarde
STATIČKI AUTOKLAV OD NEHRĐAVAJUĆEG ČELJA LAGARDE 4 B
Lagarde
Stanje
Polovno
Lokacija
Lorquí 

Slike prikazuju
Prikaži kartu
Podaci o mašini
- Naziv mašine:
- STATIČKI AUTOKLAV OD NEHRĐAVAJUĆEG ČELJA LAGARDE 4 B
- Proizvođač:
- Lagarde
- Stanje:
- skoro nov (polovno)
Cijena i lokacija
- Lokacija:
- Polígono Industrial de Lorquí Parcela 129, 30564 Lorquí, España

Pozovite
Detalji ponude
- ID oglasa:
- A20900242
- Ažuriranje:
- posljednji put 09.01.2026
Opis
Autoclaves are used for the sterilization of packaged products that need to reach high temperatures (+100ºC) for the elimination or inactivation of pathogenic microorganisms.
Static autoclaves: these are suitable for any format and are used for food packaged in cans, jars and other flexible materials.
CHARACTERISTICS:
* Forced ventilation
*Shower system.
Bodpjx S Ipwofx Afaecw
* Temperature and time recorder.
CONSUMPTIONS:
- Steam: Maximum flow rate 2100 kg/h. Approximate consumption 475 kg/cycle.
- Electrical energy in KW: 22kw
- Cold water in tn/hr: Flow rate 25m³/h.
- Compressed air in m³/min. The theoretical required to cool the autoclave in the worst air requirement condition (empty or with low load) is 2.91 m³/minute.
- Total amount of drainage in ton/day: Depends on the number of cycles. Approximately 0.8 m3/cycle will be drained from inside the autoclave at the end of the cycle. The water output of the exchanger will be the same as the water input during cooling, 25 m³/h.
- Total raw water consumption in tn/day: 0.8 m³/cycle final + 12-16 m³ cooling.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Static autoclaves: these are suitable for any format and are used for food packaged in cans, jars and other flexible materials.
CHARACTERISTICS:
* Forced ventilation
*Shower system.
Bodpjx S Ipwofx Afaecw
* Temperature and time recorder.
CONSUMPTIONS:
- Steam: Maximum flow rate 2100 kg/h. Approximate consumption 475 kg/cycle.
- Electrical energy in KW: 22kw
- Cold water in tn/hr: Flow rate 25m³/h.
- Compressed air in m³/min. The theoretical required to cool the autoclave in the worst air requirement condition (empty or with low load) is 2.91 m³/minute.
- Total amount of drainage in ton/day: Depends on the number of cycles. Approximately 0.8 m3/cycle will be drained from inside the autoclave at the end of the cycle. The water output of the exchanger will be the same as the water input during cooling, 25 m³/h.
- Total raw water consumption in tn/day: 0.8 m³/cycle final + 12-16 m³ cooling.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Dokumenti
Dobavljač
Napomena: Registrujte se besplatno ili prijavite, za pristup svim informacijama.
Pošaljite upit
Telefon & Faks
+34 968 6... oglasi
Ovi oglasi bi vas također mogli zanimati.
Mali oglas
Suffolk
1.559 km
Retorta / autoklav
Lagarde4 trolley retort
Lagarde4 trolley retort
Mali oglas
Forst
908 km
Separator / bistrič za hladno mlijeko
GEA
GEA
Mali oglas
Mouvaux
1.329 km
Stroj za preradu mesa
LagardeAutoclave SVS100
LagardeAutoclave SVS100
Mali oglas
Poznań
943 km
Autoclave Autoclave
SteritechAV20
SteritechAV20
Mali oglas
Finska
1.954 km
Mašina za preradu mesa
Steriflow1351 EL.
Steriflow1351 EL.
Mali oglas
Bury St Edmunds
1.559 km
Optički sortirac za povrće
Tomra OdenbergHalo III 2021
Tomra OdenbergHalo III 2021
Mali oglas
Sevenum
1.206 km
Vakuumski zatvarač
CalumaticMTV-6
CalumaticMTV-6
Mali oglas
Mouvaux
1.329 km
Autoklav
SteriflowBarriquand 1351
SteriflowBarriquand 1351
Mali oglas
Njemačka
922 km
Rezervoar za autoklav
Gessner1CB 0206 B101
Gessner1CB 0206 B101
Mali oglas
Janville
1.308 km
Sterilizacijski autoklav
Steriflow1321 EA
Steriflow1321 EA
Vaš oglas je uspješno izbrisan
Došlo je do greške



































































































