STATIČKI AUTOKLAV OD NEHRĐAVAJUĆEG ČELJA LAGARDE 4 BLagarde
STATIČKI AUTOKLAV OD NEHRĐAVAJUĆEG ČELJA LAGARDE 4 B
Lagarde
Stanje
Polovno
Lokacija
Lorquí 

Podaci o mašini
- Naziv mašine:
- STATIČKI AUTOKLAV OD NEHRĐAVAJUĆEG ČELJA LAGARDE 4 B
- Proizvođač:
- Lagarde
- Stanje:
- skoro nov (polovno)
Cijena i lokacija
- Lokacija:
- Polígono Industrial de Lorquí Parcela 129, 30564 Lorquí, España

Pozovite
Detalji ponude
- ID oglasa:
- A20900242
- Ažuriranje:
- posljednji put 16.04.2026
Opis
Autoclaves are used for the sterilization of packaged products that need to reach high temperatures (+100ºC) for the elimination or inactivation of pathogenic microorganisms.
Static autoclaves: these are suitable for any format and are used for food packaged in cans, jars and other flexible materials.
Lajdjx S Ipwjpfx Ac Ied
CHARACTERISTICS:
* Forced ventilation
*Shower system.
* Temperature and time recorder.
CONSUMPTIONS:
- Steam: Maximum flow rate 2100 kg/h. Approximate consumption 475 kg/cycle.
- Electrical energy in KW: 22kw
- Cold water in tn/hr: Flow rate 25m³/h.
- Compressed air in m³/min. The theoretical required to cool the autoclave in the worst air requirement condition (empty or with low load) is 2.91 m³/minute.
- Total amount of drainage in ton/day: Depends on the number of cycles. Approximately 0.8 m3/cycle will be drained from inside the autoclave at the end of the cycle. The water output of the exchanger will be the same as the water input during cooling, 25 m³/h.
- Total raw water consumption in tn/day: 0.8 m³/cycle final + 12-16 m³ cooling.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Static autoclaves: these are suitable for any format and are used for food packaged in cans, jars and other flexible materials.
Lajdjx S Ipwjpfx Ac Ied
CHARACTERISTICS:
* Forced ventilation
*Shower system.
* Temperature and time recorder.
CONSUMPTIONS:
- Steam: Maximum flow rate 2100 kg/h. Approximate consumption 475 kg/cycle.
- Electrical energy in KW: 22kw
- Cold water in tn/hr: Flow rate 25m³/h.
- Compressed air in m³/min. The theoretical required to cool the autoclave in the worst air requirement condition (empty or with low load) is 2.91 m³/minute.
- Total amount of drainage in ton/day: Depends on the number of cycles. Approximately 0.8 m3/cycle will be drained from inside the autoclave at the end of the cycle. The water output of the exchanger will be the same as the water input during cooling, 25 m³/h.
- Total raw water consumption in tn/day: 0.8 m³/cycle final + 12-16 m³ cooling.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Dokumenti
Dobavljač
Napomena: Registrujte se besplatno ili prijavite, za pristup svim informacijama.
Registriran od: 2024
100 Oglasi online
Pošaljite upit
Telefon & Faks
+34 968 6... oglasi
Ovi oglasi bi vas također mogli zanimati.
Mali oglas
Suffolk
1.559 km
Retorta / autoklav
Lagarde4 trolley retort
Lagarde4 trolley retort
Mali oglas
Niedźwiedź
659 km
Rashladni kompresor
BITZER60-70.2
BITZER60-70.2
Mali oglas
Suffolk
1.559 km
Retorti / autoklavi iz nedavno zatvorene fabrike dječje hrane
Lagarde4 trolley retorts / autoclaves
Lagarde4 trolley retorts / autoclaves
Mali oglas
Mouvaux
1.329 km
Stroj za preradu mesa
LagardeAutoclave SVS100
LagardeAutoclave SVS100
Mali oglas
Mala Vranjska
182 km
Vakum punilo
HandtmannVF 610 Vacuum filler
HandtmannVF 610 Vacuum filler
Mali oglas
Njemačka
922 km
Spremnici
Gessner1CB 0206 B101
Gessner1CB 0206 B101
Mali oglas
Mouvaux
1.329 km
Posuda za kuvanje
Process AgroMarmite de cuisson 400L
Process AgroMarmite de cuisson 400L
Mali oglas
Guiseley
1.791 km
Spiralni zamrzivač
CFS Compact spiral freezer
CFS Compact spiral freezer
Mali oglas
Zamość
866 km
Automatski rezač-mikser-emulgator
Karl SchnellFD 11
Karl SchnellFD 11
Mali oglas
Sevenum
1.206 km
Vakuumski zatvarač
CalumaticMTV-6
CalumaticMTV-6
Vaš oglas je uspješno izbrisan
Došlo je do greške



























































































