Čista SOBA ISO 8
Čista SOBA ISO 8
EXW VB plus PDV
50.000 €
godina proizvodnje
2020
Stanje
Polovno
Lokacija
Łódź 

Slike prikazuju
Prikaži kartu
Podaci o mašini
- Naziv mašine:
- Čista SOBA ISO 8
- Godina proizvodnje:
- 2020
- Stanje:
- vrlo dobro (rabljeno)
- Funkcionalnost:
- potpuno funkcionalan
Cijena i lokacija
EXW VB plus PDV
50.000 €
- Lokacija:
- Łódź, Poljska

Pozovite
Detalji ponude
- ID oglasa:
- A14477200
- Ažuriranje:
- posljednji put 02.01.2024
Opis
CLEANROOM - ISO 8
| Cleanroom requirements ISO Class 8 | ISO Cleanroom Class 8 | Cleanroom classification.
In order to achieve an ISO 8 air purity class in a Cleanroom, several levels of air filtration are usually used (e.g. G4 pre-filter, F9 filter, H13 final filter). Air movement in the room is non-unidirectional (there is a mixing of "clean" air supplied to the room with "dirty" air present in the room). Air vents in the ISO 8 room are placed on the walls. The required number of air exchanges per hour will depend on the nature of the activities conducted in the room and the number of personnel present, but the goal could be to provide 10-40 air exchanges/hr. In ISO Class 8, personnel are often present continuously. Employees may be dressed in standard work attire and visitors in a disposable apron. It is recommended to maintain a minimum overpressure of the room relative to the adjacent zone of 5-10 Pa.
Requirements for equipment and materials intended for Clean Room with ISO air cleanliness class 8 (maximum average amount of particles released when: number of samples taken = 100; measurement performed in accordance with ISO 14644-14 in a cleanliness class at least one better than the purpose of the device; number of particles/m3) Detailed description in photos.
Technical drawings attached to photos.
Description of ventilation
The purpose of the ventilation installation performed was to achieve the following air parameters in the Clean Room. The installation was made with the GBD PHARMA 2000 system, meeting all the requirements for 'clean rooms' in the highest classes of air purity.
Parameters for the installation: a. Air purity - ISO 8. b. Temperature 19-23 st C
Lrsdsq H H Rujpfx Ah Now
c. Humidity max 38%.
a. To ensure the required purity of the supplied air, an air handling unit manufactured by DOSPEL with a maximum capacity of V= 3500 m3/h [up to 15 air changes per hour] was used. The air handling unit is equipped with pocket filters : pre-filters FK EU5/EC2 and fine filters FK-EU9/EC2. In addition, HEPA 11 filters made by EUFILTER were used in diffusers located in the ceiling. Data sheets in point H6.
As a result , with a measured flow rate of 3264 m3/h, an ISO 7 [class "C"] cleanliness class of the room was obtained in the resting state, and thus an ISO 8 [class "D" ] cleanliness class for the working state.
b. The temperature range of 19-23 deg C is for the enlarged cooler and chiller to be freely maintained with 25% fresh air.
c. In order to achieve in summer conditions with high temperatures of 30 deg C and humidity of 80%, a freon chiller of 31.4 kW and a chiller of 33.5 kW of cooling power were used. The chiller is made by FUJITSU supplied by Klimatherm Gdansk.
The room is automatically regulated overpressure in relation to the external pressure - the pressure difference at the door : 15 Pa
The automation of ventilation allows for "economical" mode , in which the installation works in a closed circuit and an overpressure of 15 Pa is maintained.
Technical data attached to the photos.
Oglas je automatski preveden. Moguće su greške u prijevodu.
| Cleanroom requirements ISO Class 8 | ISO Cleanroom Class 8 | Cleanroom classification.
In order to achieve an ISO 8 air purity class in a Cleanroom, several levels of air filtration are usually used (e.g. G4 pre-filter, F9 filter, H13 final filter). Air movement in the room is non-unidirectional (there is a mixing of "clean" air supplied to the room with "dirty" air present in the room). Air vents in the ISO 8 room are placed on the walls. The required number of air exchanges per hour will depend on the nature of the activities conducted in the room and the number of personnel present, but the goal could be to provide 10-40 air exchanges/hr. In ISO Class 8, personnel are often present continuously. Employees may be dressed in standard work attire and visitors in a disposable apron. It is recommended to maintain a minimum overpressure of the room relative to the adjacent zone of 5-10 Pa.
Requirements for equipment and materials intended for Clean Room with ISO air cleanliness class 8 (maximum average amount of particles released when: number of samples taken = 100; measurement performed in accordance with ISO 14644-14 in a cleanliness class at least one better than the purpose of the device; number of particles/m3) Detailed description in photos.
Technical drawings attached to photos.
Description of ventilation
The purpose of the ventilation installation performed was to achieve the following air parameters in the Clean Room. The installation was made with the GBD PHARMA 2000 system, meeting all the requirements for 'clean rooms' in the highest classes of air purity.
Parameters for the installation: a. Air purity - ISO 8. b. Temperature 19-23 st C
Lrsdsq H H Rujpfx Ah Now
c. Humidity max 38%.
a. To ensure the required purity of the supplied air, an air handling unit manufactured by DOSPEL with a maximum capacity of V= 3500 m3/h [up to 15 air changes per hour] was used. The air handling unit is equipped with pocket filters : pre-filters FK EU5/EC2 and fine filters FK-EU9/EC2. In addition, HEPA 11 filters made by EUFILTER were used in diffusers located in the ceiling. Data sheets in point H6.
As a result , with a measured flow rate of 3264 m3/h, an ISO 7 [class "C"] cleanliness class of the room was obtained in the resting state, and thus an ISO 8 [class "D" ] cleanliness class for the working state.
b. The temperature range of 19-23 deg C is for the enlarged cooler and chiller to be freely maintained with 25% fresh air.
c. In order to achieve in summer conditions with high temperatures of 30 deg C and humidity of 80%, a freon chiller of 31.4 kW and a chiller of 33.5 kW of cooling power were used. The chiller is made by FUJITSU supplied by Klimatherm Gdansk.
The room is automatically regulated overpressure in relation to the external pressure - the pressure difference at the door : 15 Pa
The automation of ventilation allows for "economical" mode , in which the installation works in a closed circuit and an overpressure of 15 Pa is maintained.
Technical data attached to the photos.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Dobavljač
Napomena: Registrujte se besplatno ili prijavite, za pristup svim informacijama.
Registriran od: 2023
Pošaljite upit
Telefon & Faks
+48 728 4... oglasi
Ovi oglasi bi vas također mogli zanimati.
mali oglas
Baarle-Nassau
1.267 km
Schafer Logimat skladišni lift
Schäfer Logimat liftLogimat 3625 – 815 – 13.450/400
Schäfer Logimat liftLogimat 3625 – 815 – 13.450/400
mali oglas
Hochdorf
824 km
Jedinica za hlađenje temperature (TCU)
SingleOil Advanced D2
SingleOil Advanced D2
mali oglas
Burgdorf
1.108 km
Čista soba / Čista soba ISO 6
ABNStericube Matrix ISO 6
ABNStericube Matrix ISO 6
mali oglas
Niederlangen
1.258 km
Usisavanje
NOVUSAirtower FT 20.000
NOVUSAirtower FT 20.000
mali oglas
La Grand-Croix
1.051 km
Vertikalni obradni centar
centre d'usinageDMG DMF 180-7
centre d'usinageDMG DMF 180-7
mali oglas
Krotoszyn
867 km
Paker/Mašina za pakovanje
MultivacR230
MultivacR230
mali oglas
Graben-Neudorf
913 km
Mašina za vakum pakovanje
GEAPowerPak XT 420
GEAPowerPak XT 420
mali oglas
Njemačka
972 km
CNC vertikalni obradni centar
DMG MoriDMC 650 V
DMG MoriDMC 650 V
mali oglas
Laupheim
770 km
Mašina za blister pakovanje
UhlmannBEC700
UhlmannBEC700
mali oglas
Berlin
1.005 km
Blister mašina
NeopackagingBlistera NBM065
NeopackagingBlistera NBM065
Vaš oglas je uspješno izbrisan
Došlo je do greške






























































































































