Prince Technologies PrinCe 560 kapilarnozonoforetski sistem (sistem za kapilarnozonu elektroforezu)Prince Technologies
PrinCe 560
Prince Technologies PrinCe 560 kapilarnozonoforetski sistem (sistem za kapilarnozonu elektroforezu)
Prince Technologies
PrinCe 560
VB plus PDV
1.470 €
Stanje
Polovno
Lokacija
Borken 

Osnovni podaci
- Naziv mašine:
- Prince Technologies PrinCe 560 kapilarnozonoforetski sistem (sistem za kapilarnozonu elektroforezu)
- Proizvođač:
- Prince Technologies
- Model:
- PrinCe 560
- Stanje:
- polovno
Cijena i lokacija
VB plus PDV
1.470 €
- Lokacija:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Pozovite
Detalji ponude
- ID oglasa:
- A17565433
- Referentni broj:
- 12878
- Ažuriranje:
- posljednji put 13.11.2026
Opis
Prince Technologies PrinCe 560
Capillary Zone Electrophoresis System
Nsdpfx Aceu Eb D Hjrjdd
Connections:
Power supply, HV control, parallel connection A, parallel connection B,
serial connection A (RS232), serial connection B (RS232).
Technical Data:
Injection method: Up to 650 min, in 0.01 min steps; Hydrodynamics: 180 - 250 mbar, in 1 mbar steps, Electrokinetics: -30 to +30 kV, current and/or voltage.
Flow/Pressure range: 0 to +3000 mbar from DCI device.
Voltage range: -30 kV to +30 kV
Current range: -200uA to +200uA
Ramp: Programmable voltage or current ramp.
Polarity reversal: Programmable before and during the sample run.
Autosampler: Position carousel for 30/48 sample/buffer vials. Variable vial size, including Eppendorf micro centrifuge tubes.
Buffer volume: Max. 4 ml
Sample volume: Minimum 10µl, max. 4 ml.
Temperature control: Sample and buffer 4°C to 40°C.
Capillary temperature: 5°C to below 60°C.
Detector: Allows the use of: UV/Vis, fluorescence, diode array, LIF, conductivity, electrochemical, and MS.
Year of manufacture: 2004
Model: PrinCe 560 0500.022/CR
S/N: 50-14-05-3-23
Dimensions: 50x50x54 cm
Weight: 35 kg
Without functional test.
More items - new and used - can be found in our shop!
International shipping costs on request!
Oglas je automatski preveden. Moguće su greške u prijevodu.
Capillary Zone Electrophoresis System
Nsdpfx Aceu Eb D Hjrjdd
Connections:
Power supply, HV control, parallel connection A, parallel connection B,
serial connection A (RS232), serial connection B (RS232).
Technical Data:
Injection method: Up to 650 min, in 0.01 min steps; Hydrodynamics: 180 - 250 mbar, in 1 mbar steps, Electrokinetics: -30 to +30 kV, current and/or voltage.
Flow/Pressure range: 0 to +3000 mbar from DCI device.
Voltage range: -30 kV to +30 kV
Current range: -200uA to +200uA
Ramp: Programmable voltage or current ramp.
Polarity reversal: Programmable before and during the sample run.
Autosampler: Position carousel for 30/48 sample/buffer vials. Variable vial size, including Eppendorf micro centrifuge tubes.
Buffer volume: Max. 4 ml
Sample volume: Minimum 10µl, max. 4 ml.
Temperature control: Sample and buffer 4°C to 40°C.
Capillary temperature: 5°C to below 60°C.
Detector: Allows the use of: UV/Vis, fluorescence, diode array, LIF, conductivity, electrochemical, and MS.
Year of manufacture: 2004
Model: PrinCe 560 0500.022/CR
S/N: 50-14-05-3-23
Dimensions: 50x50x54 cm
Weight: 35 kg
Without functional test.
More items - new and used - can be found in our shop!
International shipping costs on request!
Oglas je automatski preveden. Moguće su greške u prijevodu.
Dobavljač
Napomena: Registrujte se besplatno ili prijavite, za pristup svim informacijama.
Posljednji put online: prošle sedmice
Registriran od: 2008
536 Oglasi online
Pošaljite upit
Telefon & Faks
+49 2862 ... oglasi
Vaš oglas je uspješno izbrisan
Došlo je do greške