Reznor plinski toplozračni generator UDSA025-3, grijanje za hale, 25,53 kW, grijalicaReznor
UDSA025-3
Reznor plinski toplozračni generator UDSA025-3, grijanje za hale, 25,53 kW, grijalica
Reznor
UDSA025-3
VB plus PDV
2.016 €
Stanje
Polovno
Lokacija
Borken 

Cijena i lokacija
VB plus PDV
2.016 €
- Lokacija:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Pozovite
Detalji ponude
- ID oglasa:
- A20781242
- Referentni broj:
- 56875
- Ažuriranje:
- posljednji put 07.10.2026
Opis
Reznor UDSA Gas-Fired Warm Air Heater
Fsdpfxsx Ihg Io Am Aopn
UDSA Gas-Fired Warm Air Heater – efficient, even at peak performance
The most well-known unit from REZNOR is the UDSA gas-fired warm air heater, which ensures even air distribution in industrial halls. This easy-to-install recirculating air unit is available in 14 performance sizes, from 7 to 97 kW, and consists of a heat exchanger, gas burner, and an exhaust gas fan. The combustion air can be drawn either from the outside or from the room, as standard.
The UDSA warm air heater from REZNOR guarantees even air distribution in the heated hall. Its patented heat exchanger sets new standards in terms of flow behavior and heat transfer, ensuring an efficiency of over 92 percent.
UDSA: compact, revolutionary, and groundbreaking.
With this generation of units, halls can be heated in a particularly economical way – directly, that is, without central heating – using decentralized, modulating gas-fired warm air heaters.
REZNOR UDSA
Gas-Fired Warm Air Heater. The advantages:
Efficiency of more than 92%
Unit is also suitable for vertical mounting
Low NOx emissions
Innovative combustion concept
Quiet operation
With CE system certification, version B or C
Compact design for easy installation
Even heat distribution
Standard vertical and horizontal air guide vanes
Modulation of the heating output up to 50%
EC technology
ErP Ready
These units are direct-fired gas warm air heaters with fan-assisted atmospheric multi-gas burners.
The installation of the gas warm air heater, including the gas and exhaust connections, must be carried out by an authorized installation company.
These gas warm air heaters are suitable for:
- Natural gas or liquefied gas operation
- Recirculating air operation
- Intake temperatures below 5°C with a stainless steel heat exchanger *
- Heating operation with 1 stage or 2 stages* Control via room thermostat and heating control switch
- Ventilation° Control via ECOtronic TN - L° with day-night-week program
- Exhaust gas extraction via roof, version B or C °
- Exhaust gas extraction through the outer wall, version C °
Gas warm air heater type: UDSA025-3
Gas appliance type: B22P-C12-C32-C52-C62
Intended use: DE
Gas category: I2ELL
Gas type: G20 Natural gas
Connection pressure: 20 mbar
Nozzle pressure: 8.20 mbar
Maximum nominal heat input (Hs) QN: 30.08 kW
Maximum nominal heat input (Hi) QN: 27.75 kW
Maximum nominal heat output: 25.53 kW
Minimum nominal heat output:
Connection voltage: 230V 1N, 50Hz
Air volume flow: 2385 m3/h
Protection class: IP20
You can find more items – new and used – in our shop!
International shipping costs on request!
Oglas je automatski preveden. Moguće su greške u prijevodu.
Fsdpfxsx Ihg Io Am Aopn
UDSA Gas-Fired Warm Air Heater – efficient, even at peak performance
The most well-known unit from REZNOR is the UDSA gas-fired warm air heater, which ensures even air distribution in industrial halls. This easy-to-install recirculating air unit is available in 14 performance sizes, from 7 to 97 kW, and consists of a heat exchanger, gas burner, and an exhaust gas fan. The combustion air can be drawn either from the outside or from the room, as standard.
The UDSA warm air heater from REZNOR guarantees even air distribution in the heated hall. Its patented heat exchanger sets new standards in terms of flow behavior and heat transfer, ensuring an efficiency of over 92 percent.
UDSA: compact, revolutionary, and groundbreaking.
With this generation of units, halls can be heated in a particularly economical way – directly, that is, without central heating – using decentralized, modulating gas-fired warm air heaters.
REZNOR UDSA
Gas-Fired Warm Air Heater. The advantages:
Efficiency of more than 92%
Unit is also suitable for vertical mounting
Low NOx emissions
Innovative combustion concept
Quiet operation
With CE system certification, version B or C
Compact design for easy installation
Even heat distribution
Standard vertical and horizontal air guide vanes
Modulation of the heating output up to 50%
EC technology
ErP Ready
These units are direct-fired gas warm air heaters with fan-assisted atmospheric multi-gas burners.
The installation of the gas warm air heater, including the gas and exhaust connections, must be carried out by an authorized installation company.
These gas warm air heaters are suitable for:
- Natural gas or liquefied gas operation
- Recirculating air operation
- Intake temperatures below 5°C with a stainless steel heat exchanger *
- Heating operation with 1 stage or 2 stages* Control via room thermostat and heating control switch
- Ventilation° Control via ECOtronic TN - L° with day-night-week program
- Exhaust gas extraction via roof, version B or C °
- Exhaust gas extraction through the outer wall, version C °
Gas warm air heater type: UDSA025-3
Gas appliance type: B22P-C12-C32-C52-C62
Intended use: DE
Gas category: I2ELL
Gas type: G20 Natural gas
Connection pressure: 20 mbar
Nozzle pressure: 8.20 mbar
Maximum nominal heat input (Hs) QN: 30.08 kW
Maximum nominal heat input (Hi) QN: 27.75 kW
Maximum nominal heat output: 25.53 kW
Minimum nominal heat output:
Connection voltage: 230V 1N, 50Hz
Air volume flow: 2385 m3/h
Protection class: IP20
You can find more items – new and used – in our shop!
International shipping costs on request!
Oglas je automatski preveden. Moguće su greške u prijevodu.
Dobavljač
Napomena: Registrujte se besplatno ili prijavite, za pristup svim informacijama.
Registriran od: 2008
540 Oglasi online
Pošaljite upit
Telefon & Faks
+49 2862 ... oglasi
Vaš oglas je uspješno izbrisan
Došlo je do greške