Izvlakač bojnih isparenjaScheuch LBH
ZLG III
Izvlakač bojnih isparenja
Scheuch LBH
ZLG III
fiksna cijena plus PDV
15.000 €
Godina proizvodnje
2010
Stanje
Polovno
Lokacija
Raasdorf bei Wien 

Podaci o mašini
- Naziv mašine:
- Izvlakač bojnih isparenja
- Proizvođač:
- Scheuch LBH
- Model:
- ZLG III
- Godina proizvodnje:
- 2010
- Stanje:
- skoro nov (polovno)
Cijena i lokacija
fiksna cijena plus PDV
15.000 €
- Lokacija:
- Die Marchenfelderstr 13A, 2281 Raasdorf, Österreich

Pozovite
Detalji ponude
- ID oglasa:
- A22323692
- Ažuriranje:
- posljednji put 13.07.2026
Opis
MAKE-UP AND EXHAUST AIR SYSTEM
for PAINTING and DRYING BOOTH
Air flow rate: 10,000 m³/h
-SUPPLY AIR UNIT Type ZLG III
including duct components in galvanized design
Technical data:
Manufacturer: LBH
Type: ZLG III
Air volume: 10,000 m³/h
Motor power: 3.0 kW
Operating voltage: 230 / 400 V
Frequency: 50 Hz
Speed: 1,435 min⁻¹
Motor design: B 3
Total pressure differential: 450 Pa
Heating coil: Cu / Al
Tube rows: 3 pieces
Heating capacity: 124 kW
Heating medium: 80 / 60 °C water
Air inlet temperature: -15 °C
Air outlet temperature: +22 °C
Filter area: 14.44 m²
Water-side resistance: 550 mm WG
Circulation rate: 5,345 l/h
Water connections supply/return: DN 32
Sound pressure level
at 3 m distance from the unit: 62 dB(A)
Sound pressure level
at 3 m distance from
the intake point: 55 dB(A)
-DRY SPRAY WALL 4 x 1 m
with PAPER and AFTERFILTER UNIT
and guide vanes
Technical data: W x H x D = 4,000 x 1,000 x 400 mm
-FLOOR SUCTION DUCT for drying area
Technical data:
Suction diameter: 220 mm
Cross-section: 250 x 250 mm
Length: approx. 6,000 mm
-EXHAUST AIR COMPONENTS
Technical data:
Manufacturer: LBH
Sound pressure level measured at 3 m distance
from the exhaust air deflector hood: 58 dB(A)
-EXHAUST AIR FAN TYPE VGM-071-0450-K / 4.0 kW
Technical data:
Manufacturer: LBH
Type: VGM-071-0450-K
Air volume: 10,000 m³/h
Motor power: 4.0 kW
Operating voltage: 230 / 400 V
Frequency: 50 Hz
Speed: 1,500 min⁻¹
Motor design: B 3
Total pressure differential: 1,000 Pa
Housing position: GR 90°
Sound pressure level
at 3 m distance: 68 dB(A)
Gijdjzlktpspfx Ab Ujw
-SWITCH AND CONTROL CABINET
Make-up and exhaust air system
for PAINTING and DRYING BOOTH
(including frequency converter)
Switchboard for controlling all units,
as well as for monitoring and regulating the frost protection limit,
the supply air temperature, including frost protection sensor and supply air sensor
The following functions are located on the front door of the switchboard: - Main switch to switch on the entire system - Emergency stop button to lock the entire system - On/off button to activate the control system - Selector switch for switching between manual and automatic operation of the heating pump - Operating indicators (green) and fault indicators (red) for supply and exhaust air fans - Release button to start the system in the event of possible malfunctions (frost protection louver), as well as a fault indicator lamp.
The technology:
in the switchboard includes: - Frequency converter for supply and exhaust air motors - Motor protection switch for all motors, if required, with the corresponding contactors, - PLC control, - Connection terminals for all external control devices such as frost protection sensor, supply air sensor, mixing valve, ... - an external fault output.
-MOTOR-OPERATED THREE-WAY VALVE with geared actuator
RUNNING TIME SAVER SWITCH incl. MOUNTING PLATE
in explosion-proof design (ATEX design)
The running time saver switch is used to automatically start and switch off the make-up and exhaust air system after completion of the spraying process, or to switch between spraying and drying mode.
The painting system was used in a training workshop and is in absolutely new condition.
New price of the system: 36,800 EUR (2010)
The system has already been dismantled and is stored in warehouse 2281 Raasdorf
Price: 15,000 EUR
Oglas je automatski preveden. Moguće su greške u prijevodu.
for PAINTING and DRYING BOOTH
Air flow rate: 10,000 m³/h
-SUPPLY AIR UNIT Type ZLG III
including duct components in galvanized design
Technical data:
Manufacturer: LBH
Type: ZLG III
Air volume: 10,000 m³/h
Motor power: 3.0 kW
Operating voltage: 230 / 400 V
Frequency: 50 Hz
Speed: 1,435 min⁻¹
Motor design: B 3
Total pressure differential: 450 Pa
Heating coil: Cu / Al
Tube rows: 3 pieces
Heating capacity: 124 kW
Heating medium: 80 / 60 °C water
Air inlet temperature: -15 °C
Air outlet temperature: +22 °C
Filter area: 14.44 m²
Water-side resistance: 550 mm WG
Circulation rate: 5,345 l/h
Water connections supply/return: DN 32
Sound pressure level
at 3 m distance from the unit: 62 dB(A)
Sound pressure level
at 3 m distance from
the intake point: 55 dB(A)
-DRY SPRAY WALL 4 x 1 m
with PAPER and AFTERFILTER UNIT
and guide vanes
Technical data: W x H x D = 4,000 x 1,000 x 400 mm
-FLOOR SUCTION DUCT for drying area
Technical data:
Suction diameter: 220 mm
Cross-section: 250 x 250 mm
Length: approx. 6,000 mm
-EXHAUST AIR COMPONENTS
Technical data:
Manufacturer: LBH
Sound pressure level measured at 3 m distance
from the exhaust air deflector hood: 58 dB(A)
-EXHAUST AIR FAN TYPE VGM-071-0450-K / 4.0 kW
Technical data:
Manufacturer: LBH
Type: VGM-071-0450-K
Air volume: 10,000 m³/h
Motor power: 4.0 kW
Operating voltage: 230 / 400 V
Frequency: 50 Hz
Speed: 1,500 min⁻¹
Motor design: B 3
Total pressure differential: 1,000 Pa
Housing position: GR 90°
Sound pressure level
at 3 m distance: 68 dB(A)
Gijdjzlktpspfx Ab Ujw
-SWITCH AND CONTROL CABINET
Make-up and exhaust air system
for PAINTING and DRYING BOOTH
(including frequency converter)
Switchboard for controlling all units,
as well as for monitoring and regulating the frost protection limit,
the supply air temperature, including frost protection sensor and supply air sensor
The following functions are located on the front door of the switchboard: - Main switch to switch on the entire system - Emergency stop button to lock the entire system - On/off button to activate the control system - Selector switch for switching between manual and automatic operation of the heating pump - Operating indicators (green) and fault indicators (red) for supply and exhaust air fans - Release button to start the system in the event of possible malfunctions (frost protection louver), as well as a fault indicator lamp.
The technology:
in the switchboard includes: - Frequency converter for supply and exhaust air motors - Motor protection switch for all motors, if required, with the corresponding contactors, - PLC control, - Connection terminals for all external control devices such as frost protection sensor, supply air sensor, mixing valve, ... - an external fault output.
-MOTOR-OPERATED THREE-WAY VALVE with geared actuator
RUNNING TIME SAVER SWITCH incl. MOUNTING PLATE
in explosion-proof design (ATEX design)
The running time saver switch is used to automatically start and switch off the make-up and exhaust air system after completion of the spraying process, or to switch between spraying and drying mode.
The painting system was used in a training workshop and is in absolutely new condition.
New price of the system: 36,800 EUR (2010)
The system has already been dismantled and is stored in warehouse 2281 Raasdorf
Price: 15,000 EUR