Tečna hromatografija visokih performansi (HPLC)ThermoFisher / Dionex
UltiMate 3000
Tečna hromatografija visokih performansi (HPLC)
ThermoFisher / Dionex
UltiMate 3000
fiksna cijena plus PDV
10.000 €
Stanje
Polovno
Lokacija
Borken 

Podaci o mašini
- Naziv mašine:
- Tečna hromatografija visokih performansi (HPLC)
- Proizvođač:
- ThermoFisher / Dionex
- Model:
- UltiMate 3000
- Stanje:
- polovno
Cijena i lokacija
fiksna cijena plus PDV
10.000 €
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Pozovite
Detalji ponude
- ID oglasa:
- A22257747
- Referentni broj:
- 24837
- Ažuriranje:
- posljednji put 03.07.2026
Opis
Dionex / ThermoFisher
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min (at 23 °C ambient temperature, ±0.5 °C)
Cooling time: From 50 to 20 °C in less than 35 min (at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Column recognition: Electronic identification system for 3 columns
Switching valves: 1 or 2 thermostated microvalves with low dispersion (10 ports or 6 ports)
Fsdpfxszikcxo Afaopi
Flow splitter: Nano, capillary, or thermostated micro-flow splitter with flow splitter identification system
Flow control: Electronically controlled and actively balanced flow splitter, independent of solvent composition and backpressure
Column flow range: 50 nL/min to 2.5 mL/min using a predefined splitter and active flow control
Flow range selection:
50 nL/min to 1,000 nL/min (using a Nano-LC splitter)
0.5 μL/min to 10 μL/min (using a capillary LC splitter)
10 μL/min to 160 μL/min (using a micro-LC splitter)
Gradient delay time: Typically 600 nm.
Noise:
At a wavelength:
Oglas je automatski preveden. Moguće su greške u prijevodu.
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min (at 23 °C ambient temperature, ±0.5 °C)
Cooling time: From 50 to 20 °C in less than 35 min (at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Column recognition: Electronic identification system for 3 columns
Switching valves: 1 or 2 thermostated microvalves with low dispersion (10 ports or 6 ports)
Fsdpfxszikcxo Afaopi
Flow splitter: Nano, capillary, or thermostated micro-flow splitter with flow splitter identification system
Flow control: Electronically controlled and actively balanced flow splitter, independent of solvent composition and backpressure
Column flow range: 50 nL/min to 2.5 mL/min using a predefined splitter and active flow control
Flow range selection:
50 nL/min to 1,000 nL/min (using a Nano-LC splitter)
0.5 μL/min to 10 μL/min (using a capillary LC splitter)
10 μL/min to 160 μL/min (using a micro-LC splitter)
Gradient delay time: Typically 600 nm.
Noise:
At a wavelength:
Oglas je automatski preveden. Moguće su greške u prijevodu.
Pošaljite upit
Telefon & Faks
+49 2861 ... oglasi
Vaš oglas je uspješno izbrisan
Došlo je do greške