Svlačionica za čist prostorULKEY
Svlačionica za čist prostor
ULKEY
Godina proizvodnje
2017
Stanje
Polovno
Lokacija
Tamási 

Slike prikazuju
Prikaži kartu
Podaci o mašini
- Naziv mašine:
- Svlačionica za čist prostor
- Proizvođač:
- ULKEY
- Godina proizvodnje:
- 2017
- Stanje:
- dobar (korišteno)
Cijena i lokacija
- Lokacija:
- Tamási, 7090 Ungarn

Pozovite
Detalji ponude
- ID oglasa:
- A21169237
- Referentni broj:
- 8000001
- Ažuriranje:
- posljednji put 05.02.2026
Opis
Changing Room and Personal Entry Area:
Dimensions: 2000 x 2000 x 3000 mm
The changing room is divided into two zones: a gray zone and a white zone.
In the gray zone, personnel remove the footwear and gowns worn in the assembly area, sit on the bench separating the zones, and change into cleanroom footwear and gowns. Whenever personnel leave the cleanroom during operations, they must always change their attire upon re-entry.
Cleanroom:
Dimensions: 5500 x 4500 x 3000 mm
The goods-in zone is separated from the cleanroom adhesive area (1750 x 750 x 3000 mm).
Doors and windows between the goods-in zone and the cleanroom are interlocked; only one door or window can be opened at a time.
Upon entry: doors only open after a 6-minute delay, except when issuing storage devices, when no 6-minute lockout is applied.
After processing, the glued products are mechanically transferred to the assembly area via a pass-through window. Delivery windows must always be closed after the transfer process.
Cpsdpfxsyhbczj Ab Isu
The cleanroom is pressurized, regulated via control dampers.
Air of ISO8 quality is supplied to the cleanroom through filters installed in the air handling unit.
Air handling units are installed on the support structure above the cleanroom ceiling.
Air cleanliness is continuously monitored and recorded.
If air cleanliness falls below acceptable levels, a visual alarm notifies personnel, or intervention in the production process occurs and doors and windows are locked.
Supply Fan:
Air volume: 8,000 m³/h
Static pressure: 400 Pa
400 V, 50 Hz, k kW
With silencer
Ventilation ductwork
HEPA filter
Frame Structure:
Powder-coated
Manufactured from cold-rolled profile materials
Side Walls, Roof Structure:
LV80 Kingspan sandwich panels
3 fixed windows, transparent and thermally insulated
2 entry doors, each with a fixed, transparent upper window
2 hatch doors, each with a fixed, transparent upper window
1 outlet opening with sliding window sash
Electrical Control:
Electrical distribution cabinet
Control cabinet
Frequency converter
Measuring instruments
Monitoring System:
Vision monitoring system
Data storage computing unit (laptop)
Changing Room Furnishings:
Gray zone:
- Shoe storage
- Coat storage
- Hanging zone
- Dividing floor
Oglas je automatski preveden. Moguće su greške u prijevodu.
Dimensions: 2000 x 2000 x 3000 mm
The changing room is divided into two zones: a gray zone and a white zone.
In the gray zone, personnel remove the footwear and gowns worn in the assembly area, sit on the bench separating the zones, and change into cleanroom footwear and gowns. Whenever personnel leave the cleanroom during operations, they must always change their attire upon re-entry.
Cleanroom:
Dimensions: 5500 x 4500 x 3000 mm
The goods-in zone is separated from the cleanroom adhesive area (1750 x 750 x 3000 mm).
Doors and windows between the goods-in zone and the cleanroom are interlocked; only one door or window can be opened at a time.
Upon entry: doors only open after a 6-minute delay, except when issuing storage devices, when no 6-minute lockout is applied.
After processing, the glued products are mechanically transferred to the assembly area via a pass-through window. Delivery windows must always be closed after the transfer process.
Cpsdpfxsyhbczj Ab Isu
The cleanroom is pressurized, regulated via control dampers.
Air of ISO8 quality is supplied to the cleanroom through filters installed in the air handling unit.
Air handling units are installed on the support structure above the cleanroom ceiling.
Air cleanliness is continuously monitored and recorded.
If air cleanliness falls below acceptable levels, a visual alarm notifies personnel, or intervention in the production process occurs and doors and windows are locked.
Supply Fan:
Air volume: 8,000 m³/h
Static pressure: 400 Pa
400 V, 50 Hz, k kW
With silencer
Ventilation ductwork
HEPA filter
Frame Structure:
Powder-coated
Manufactured from cold-rolled profile materials
Side Walls, Roof Structure:
LV80 Kingspan sandwich panels
3 fixed windows, transparent and thermally insulated
2 entry doors, each with a fixed, transparent upper window
2 hatch doors, each with a fixed, transparent upper window
1 outlet opening with sliding window sash
Electrical Control:
Electrical distribution cabinet
Control cabinet
Frequency converter
Measuring instruments
Monitoring System:
Vision monitoring system
Data storage computing unit (laptop)
Changing Room Furnishings:
Gray zone:
- Shoe storage
- Coat storage
- Hanging zone
- Dividing floor