BAC S15E 1018-10 LE otvoreni rashladni toranjBAC
S1500E
BAC S15E 1018-10 LE otvoreni rashladni toranj
BAC
S1500E
VB plus PDV
26.800 €
Stanje
Polovno
Lokacija
Borken 

Podaci o mašini
- Naziv mašine:
- BAC S15E 1018-10 LE otvoreni rashladni toranj
- Proizvođač:
- BAC
- Model:
- S1500E
- Stanje:
- dobar (korišteno)
Cijena i lokacija
VB plus PDV
26.800 €
- Lokacija:
- 46325 Borken, Deutschland

Pozovite
Detalji ponude
- ID oglasa:
- A21340202
- Referentni broj:
- 60821
- Ažuriranje:
- posljednji put 02.06.2026
Opis
BAC S1500E Cooling Tower
Hfsdpfx Aboynkbmsvjh
The BAC S15E 1018-10-LE is a high-performance open cooling tower from the S1500E series by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large HVAC systems where high efficiency and ease of maintenance are top priorities.
Technology
Patented BACross III fill system, which allows for easy inspection of the fill sheets to prevent biological growth (e.g., Legionella).
Key Features of the S1500E Series
Maintenance Access: A large, inward-swinging access door and internal maintenance platforms allow technicians to comfortably perform inspections while standing inside the unit.
Hygiene Control: The design minimizes stagnant water and, thanks to special air inlet louvers, provides protection against sunlight, thereby reducing algae growth.
Flexibility: Due to the single-sided air inlet, the cooling tower can be installed even in confined spaces or positioned directly against walls.
Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
Industrial Cooling: Used in factories for process cooling.
HVAC: Deployed in large building complexes as part of the central cooling plant.
Refrigeration: Serves as a condenser in commercial refrigeration circuits.
Cooling Capacity
An open evaporative cooling tower does not possess a single, fixed kW cooling capacity, as the actual performance depends entirely on thermodynamic ambient conditions and system temperatures.
The model is designed for maximum flow rates of up to 198 liters per second. Under typical industrial or standard HVAC conditions, the nominal cooling capacity of this model ranges from approximately 1,200 kW to 2,100 kW.
Why does cooling capacity vary?
Wet-bulb temperature (ambient air): The cooler and drier the ambient air, the more water can evaporate, resulting in a higher cooling capacity.
Water temperatures: Performance varies significantly depending on the incoming hot water temperature (e.g., 35 °C) and the outgoing cold water temperature (e.g., 29 °C).
Air volume flow: According to BAC’s technical specifications, the S15E 1018-10 LE model actively moves 60.0 m³/s of air using three installed 11.0 kW fan motors.
If this airflow volume is reduced via a variable frequency drive (e.g., during night operation or in winter), the cooling capacity decreases in a controlled manner.
Approach: This represents the most critical thermodynamic limit. It describes the temperature difference between the desired cold water temperature and the prevailing wet-bulb temperature. The closer the cold water is required to be cooled to the wet-bulb temperature (i.e., a smaller approach), the lower the cooling capacity the tower can deliver. Technical Specifications:
Fan & Air Data
Airflow Rate: 60.0 m³/s (generated in suction mode)
Fan Motors: 3x 11.0 kW (Axial fans)
Technology: Integrated belt drive
Water Flow Rate: 198 l/s
Hydraulic Connections
Water Inlet (Fluid Inlet): 1x DN 250 (Nominal Diameter ND 250 mm)
Water Outlet (Fluid Outlet): 1x DN 300 (Nominal Diameter ND 300 mm)
Fresh Water Connection (Make-up): 1x DN 40 (ND 40 mm)
Overflow / Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Hfsdpfx Aboynkbmsvjh
The BAC S15E 1018-10-LE is a high-performance open cooling tower from the S1500E series by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large HVAC systems where high efficiency and ease of maintenance are top priorities.
Technology
Patented BACross III fill system, which allows for easy inspection of the fill sheets to prevent biological growth (e.g., Legionella).
Key Features of the S1500E Series
Maintenance Access: A large, inward-swinging access door and internal maintenance platforms allow technicians to comfortably perform inspections while standing inside the unit.
Hygiene Control: The design minimizes stagnant water and, thanks to special air inlet louvers, provides protection against sunlight, thereby reducing algae growth.
Flexibility: Due to the single-sided air inlet, the cooling tower can be installed even in confined spaces or positioned directly against walls.
Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
Industrial Cooling: Used in factories for process cooling.
HVAC: Deployed in large building complexes as part of the central cooling plant.
Refrigeration: Serves as a condenser in commercial refrigeration circuits.
Cooling Capacity
An open evaporative cooling tower does not possess a single, fixed kW cooling capacity, as the actual performance depends entirely on thermodynamic ambient conditions and system temperatures.
The model is designed for maximum flow rates of up to 198 liters per second. Under typical industrial or standard HVAC conditions, the nominal cooling capacity of this model ranges from approximately 1,200 kW to 2,100 kW.
Why does cooling capacity vary?
Wet-bulb temperature (ambient air): The cooler and drier the ambient air, the more water can evaporate, resulting in a higher cooling capacity.
Water temperatures: Performance varies significantly depending on the incoming hot water temperature (e.g., 35 °C) and the outgoing cold water temperature (e.g., 29 °C).
Air volume flow: According to BAC’s technical specifications, the S15E 1018-10 LE model actively moves 60.0 m³/s of air using three installed 11.0 kW fan motors.
If this airflow volume is reduced via a variable frequency drive (e.g., during night operation or in winter), the cooling capacity decreases in a controlled manner.
Approach: This represents the most critical thermodynamic limit. It describes the temperature difference between the desired cold water temperature and the prevailing wet-bulb temperature. The closer the cold water is required to be cooled to the wet-bulb temperature (i.e., a smaller approach), the lower the cooling capacity the tower can deliver. Technical Specifications:
Fan & Air Data
Airflow Rate: 60.0 m³/s (generated in suction mode)
Fan Motors: 3x 11.0 kW (Axial fans)
Technology: Integrated belt drive
Water Flow Rate: 198 l/s
Hydraulic Connections
Water Inlet (Fluid Inlet): 1x DN 250 (Nominal Diameter ND 250 mm)
Water Outlet (Fluid Outlet): 1x DN 300 (Nominal Diameter ND 300 mm)
Fresh Water Connection (Make-up): 1x DN 40 (ND 40 mm)
Overflow / Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Dobavljač
Napomena: Registrujte se besplatno ili prijavite, za pristup svim informacijama.
Registriran od: 2008
565 Oglasi online
Pošaljite upit
Telefon & Faks
+49 2862 ... oglasi
Ovi oglasi bi vas također mogli zanimati.
Mali oglas
Łęczna
909 km
Rashladni uređaj/toplotna pumpa
New Сhiller / Heat pumpBlue Box 16/18 kW | With warranty
New Сhiller / Heat pumpBlue Box 16/18 kW | With warranty
Mali oglas
Niedźwiedź
659 km
Kompresorska jedinica
BITZER4NCS-12.2Y-40-40P (x4)
BITZER4NCS-12.2Y-40-40P (x4)
Mali oglas
Niedźwiedź
659 km
Kondenzator
GüntnerGVH 090.2A/2x5-N(D)
GüntnerGVH 090.2A/2x5-N(D)
Mali oglas
Hillegom
1.345 km
Suhi hladnjak
CaberoGCHSD089MB/X7S-40 Y V
CaberoGCHSD089MB/X7S-40 Y V
Mali oglas
Rumunija
974 km
Engel DUO 3550/400 pico
EngelDUO 3550/400 pico
EngelDUO 3550/400 pico
Mali oglas
Lanaken
1.191 km
Pločasti izmjenjivač topline
SondexSF160
SondexSF160
Mali oglas
Enschede
1.224 km
Mašina za brizganje
ENGELE-VICTORY 765H/170W/400 COMBI
ENGELE-VICTORY 765H/170W/400 COMBI
Mali oglas
Niedźwiedź
659 km
Suhi hladnjak
CaberoS-GC/DED 095 KA/2X4E
CaberoS-GC/DED 095 KA/2X4E
Mali oglas
Ecquevilly
1.329 km
Rashladna jedinica
Copeland EmersonZXLE 50
Copeland EmersonZXLE 50
Aukcija
Aukcija završena
Baden-Württemberg
871 km
Žičana EDM mašina
MITSUBISHIFA 10S Advance
MITSUBISHIFA 10S Advance
Vaš oglas je uspješno izbrisan
Došlo je do greške

































































































