Tehnički detalji
- Vrsta ulazne struje:
- Klima uređaj
- Ulazni napon:
- 400 V
- Tip hlađenja:
- voda
- Ukupna širina:
- 2.430 mm
- Ukupna dužina:
- 12.080 mm
- Ukupna visina:
- 2.880 mm
- Gorivo:
- dizel
- Ukupna masa:
- 18.000 kg
- Kontinuirana (prividna) snaga:
- 770 kVA
- Kontinuirana snaga:
- 616 kW (837,53 KS)
- Maksimalna brzina okretanja:
- 1.500 okret/min
- Zapremina motora:
- 16.400 cm³
- Kapacitet rezervoara za gorivo:
- 9.000 l
- Kapacitet rezervoara:
- 9.000 l
- Snaga:
- 616 kW (837,53 KS)
- Nazivna (prividna) snaga:
- 770 kVA
- Ulazna frekvencija:
- 50 Hz
- Oprema:
- beskonačno promjenjiva brzina rotacije, dokumentacija / priručnik
Detalji ponude
- ID oglasa:
- A18494271
- ažuriranje:
- posljednji put 23.06.2025
Opis
EPS-C40 770S - 72h Container Emergency Power Supply Unit:
AVAILABLE IMMEDIATELY!!!!
GT770S 770 700 Scania DC16 078A 02 43 400/230V 50Hz-LS
Rated power PRP: 700.0 kVA, 560.0 kW cos Phi = 0.8
Rated power LTP: 770.0 kVA, 616.0 kW cos Phi = 0.8
Reference conditions according to DIN ISO 8528
Speed: 1500 rpm
Design: Stationary
Engine:
Scania DC16 078A 02 43, four-stroke diesel engine, liquid-cooled, crankcase ventilation
returned to the engine block, fuel system with pre-filter, filter, and water separator,
combustion air filter with vacuum indicator, fuel hoses for connection of supply and return lines
with flexible transition. Electric starter,
engine shut-off device, and electronically governed speed regulator.
Rated power: 596.0 kW
Rated speed: 1500 rpm
Cylinders: 8-cylinder V
Displacement: 16,400 cm³
Leroy Somer LSA 49.3 M6
4-pole three-phase synchronous generator
Continuous output: 730.0 kVA at 40°C
Rated voltage: 400V
Rated frequency: 50Hz
Manual engine oil change pump from 700 kVA
Manual pump for emptying the engine oil pan.
Electric engine preheater 1000W up to 700 kVA 1.00 unit
The preheated coolant circulates in the primary cooling circuit of the engine
Lrjdpevyp H Uofx Aflou
via convection. Connected with flexible coolant hoses to the engine’s internal cooling circuit,
equipped with shut-off valves for maintenance accessibility.
Coolant recirculation pump ensures safe preheating of the engine.
Walls and ceiling made from pressed steel plate. Derusting and cleaning accomplished by
sandblasting the welded structure. The container is coated inside and out with
marine-grade primers and paints for seawater resistance.
Container 40" HC High Cube Soundproofed
Container ISO 1496-1 for power generation units, external dimensions according to ISO 668.
Wall and roof panels are insulated with self-extinguishing, oil- and water-resistant
sound insulation material, enclosed with glass fibre matting and electro-galvanized coated perforated sheet metal cassettes.
The exhaust silencer is housed in a separate compartment within the container.
Radiant heat is safely discharged vertically with the cooling airflow from the front-mounted radiator.
Air intake openings are installed in the wall surfaces; air exhaust outlet in the roof.
The exhaust outlet of the silencer is protected by an exhaust flap against the ingress of water.
One front side is equipped with double-leaf doors with circumferential sealing and
serves as an inspection opening.
Side personnel doors, with emergency release and circumferential sealing, provide access for
maintenance work.
The silencer and exhaust compartment is also fitted with an access door.
Plant operation is performed externally.
The control system and indicators can be viewed through an inspection window even when the
door of the control panel is closed.
The emergency stop button is protected from damage and mounted in a recessed housing niche.
Cable entry can be made from the side or through the container floor. The floor entry is prepared for
annular space seals DN 150.
40" Container collection tray according to WHG
Oil-tight welded checker plate floor with surrounding upstand, min. 50 mm
And much more…
Special feature: MAINS PARALLEL operation possible!!!
Oglas je automatski preveden. Moguće su greške u prijevodu.
AVAILABLE IMMEDIATELY!!!!
GT770S 770 700 Scania DC16 078A 02 43 400/230V 50Hz-LS
Rated power PRP: 700.0 kVA, 560.0 kW cos Phi = 0.8
Rated power LTP: 770.0 kVA, 616.0 kW cos Phi = 0.8
Reference conditions according to DIN ISO 8528
Speed: 1500 rpm
Design: Stationary
Engine:
Scania DC16 078A 02 43, four-stroke diesel engine, liquid-cooled, crankcase ventilation
returned to the engine block, fuel system with pre-filter, filter, and water separator,
combustion air filter with vacuum indicator, fuel hoses for connection of supply and return lines
with flexible transition. Electric starter,
engine shut-off device, and electronically governed speed regulator.
Rated power: 596.0 kW
Rated speed: 1500 rpm
Cylinders: 8-cylinder V
Displacement: 16,400 cm³
Leroy Somer LSA 49.3 M6
4-pole three-phase synchronous generator
Continuous output: 730.0 kVA at 40°C
Rated voltage: 400V
Rated frequency: 50Hz
Manual engine oil change pump from 700 kVA
Manual pump for emptying the engine oil pan.
Electric engine preheater 1000W up to 700 kVA 1.00 unit
The preheated coolant circulates in the primary cooling circuit of the engine
Lrjdpevyp H Uofx Aflou
via convection. Connected with flexible coolant hoses to the engine’s internal cooling circuit,
equipped with shut-off valves for maintenance accessibility.
Coolant recirculation pump ensures safe preheating of the engine.
Walls and ceiling made from pressed steel plate. Derusting and cleaning accomplished by
sandblasting the welded structure. The container is coated inside and out with
marine-grade primers and paints for seawater resistance.
Container 40" HC High Cube Soundproofed
Container ISO 1496-1 for power generation units, external dimensions according to ISO 668.
Wall and roof panels are insulated with self-extinguishing, oil- and water-resistant
sound insulation material, enclosed with glass fibre matting and electro-galvanized coated perforated sheet metal cassettes.
The exhaust silencer is housed in a separate compartment within the container.
Radiant heat is safely discharged vertically with the cooling airflow from the front-mounted radiator.
Air intake openings are installed in the wall surfaces; air exhaust outlet in the roof.
The exhaust outlet of the silencer is protected by an exhaust flap against the ingress of water.
One front side is equipped with double-leaf doors with circumferential sealing and
serves as an inspection opening.
Side personnel doors, with emergency release and circumferential sealing, provide access for
maintenance work.
The silencer and exhaust compartment is also fitted with an access door.
Plant operation is performed externally.
The control system and indicators can be viewed through an inspection window even when the
door of the control panel is closed.
The emergency stop button is protected from damage and mounted in a recessed housing niche.
Cable entry can be made from the side or through the container floor. The floor entry is prepared for
annular space seals DN 150.
40" Container collection tray according to WHG
Oil-tight welded checker plate floor with surrounding upstand, min. 50 mm
And much more…
Special feature: MAINS PARALLEL operation possible!!!
Oglas je automatski preveden. Moguće su greške u prijevodu.
Dobavljač
Napomena: Registrujte se besplatno ili prijavite, za pristup svim informacijama.
Pošaljite upit
Telefon & Faks
+43 5552 ... oglasi
Vaš oglas je uspješno izbrisan
Došlo je do greške