CTS klimatska ispitna komora CW-60/5,5, temperaturni raspon od -60°C do +100°C, zapremina 5500 litarCTS
Klimakammer CW -60/5,5
CTS klimatska ispitna komora CW-60/5,5, temperaturni raspon od -60°C do +100°C, zapremina 5500 litar
CTS
Klimakammer CW -60/5,5
Stanje
Polovno
Lokacija
Borken 

Osnovni podaci
- Naziv mašine:
- CTS klimatska ispitna komora CW-60/5,5, temperaturni raspon od -60°C do +100°C, zapremina 5500 litar
- Proizvođač:
- CTS
- Model:
- Klimakammer CW -60/5,5
- Stanje:
- polovno
Cijena i lokacija
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Pozovite
Detalji ponude
- ID oglasa:
- A22271307
- Referentni broj:
- 24907
- Ažuriranje:
- posljednji put 15.10.2026
Opis
CTS
CTS CW‑60/5.5 – Water-Cooled Climatic Test Chamber
The CW‑60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized,
walk-in or drive-in climatic chamber for performing temperature
and humidity tests on multiple test specimens simultaneously.
Device Description
The climatic test chamber can be used to test the function or material properties of a test specimen
under temperature and humidity conditions.
The efficient air circulation with a correspondingly high air exchange rate guarantees
good heat transfer to the test specimen.
The air handling unit is located on the rear of the interior chamber.
The components are located in a separate frame behind the device and are easily accessible.
The control system is housed in a separate control cabinet.
The operating panel is integrated into the control cabinet door.
To dehumidify the test chamber, the chamber is equipped with a self-regenerating compressed air dryer.
The test chamber can be purged with fresh air using a fan.
Technical Performance Data:
Temperature Tests:
Temperature range: -60 °C to +100 °C
Temperature deviation: ±0.5 to 1 K over time
Temperature change rate: linear, depending on the test specimen
and with heat radiation, measured in the supply air
Heating: 2 K/min from -40 °C to +85 °C
Cooling: 2 K/min from +85 °C to -40 °C
Climatic Tests:
Temperature range: +10 °C to +90 °C
Humidity range: 10 % to 95 % relative humidity
in the dew point range: +5 °C to +89 °C
Temperature deviation: ± 0.5 K over time
Humidity deviation: ±1 to ±3 % RH over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400 V, without test specimen, without radiation, and without additional equipment.
Dimensions:
Internal dimensions (test chamber / usable space):
Volume: approx. 5,500 liters (5.5 m³)
Internal dimensions (approx.): Height: 2300 mm, Width: 1600 mm, Depth: 1550 mm
External dimensions: Height: 2800 mm, Width: 2250 mm, Depth: 5000 mm
Operating Data:
Hodpfx Afozizmno Tefn
Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
Rated power: 58.3 kW (incl. 5 sockets)
Rated current: 86.0 A
Protection class: IP 54
Technical Design:
Refrigeration unit:
water-cooled, low noise, semi-hermetic,
stepless power adjustment through electronic
monitoring and control system,
environmentally friendly refrigerant R 23 / R 404 A
Notes
Inspection possible by appointment (46325 Borken)
Shipping by freight forwarder possible – costs & organization on request
Scope of supply: (See image)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Oglas je automatski preveden. Moguće su greške u prijevodu.
CTS CW‑60/5.5 – Water-Cooled Climatic Test Chamber
The CW‑60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized,
walk-in or drive-in climatic chamber for performing temperature
and humidity tests on multiple test specimens simultaneously.
Device Description
The climatic test chamber can be used to test the function or material properties of a test specimen
under temperature and humidity conditions.
The efficient air circulation with a correspondingly high air exchange rate guarantees
good heat transfer to the test specimen.
The air handling unit is located on the rear of the interior chamber.
The components are located in a separate frame behind the device and are easily accessible.
The control system is housed in a separate control cabinet.
The operating panel is integrated into the control cabinet door.
To dehumidify the test chamber, the chamber is equipped with a self-regenerating compressed air dryer.
The test chamber can be purged with fresh air using a fan.
Technical Performance Data:
Temperature Tests:
Temperature range: -60 °C to +100 °C
Temperature deviation: ±0.5 to 1 K over time
Temperature change rate: linear, depending on the test specimen
and with heat radiation, measured in the supply air
Heating: 2 K/min from -40 °C to +85 °C
Cooling: 2 K/min from +85 °C to -40 °C
Climatic Tests:
Temperature range: +10 °C to +90 °C
Humidity range: 10 % to 95 % relative humidity
in the dew point range: +5 °C to +89 °C
Temperature deviation: ± 0.5 K over time
Humidity deviation: ±1 to ±3 % RH over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400 V, without test specimen, without radiation, and without additional equipment.
Dimensions:
Internal dimensions (test chamber / usable space):
Volume: approx. 5,500 liters (5.5 m³)
Internal dimensions (approx.): Height: 2300 mm, Width: 1600 mm, Depth: 1550 mm
External dimensions: Height: 2800 mm, Width: 2250 mm, Depth: 5000 mm
Operating Data:
Hodpfx Afozizmno Tefn
Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
Rated power: 58.3 kW (incl. 5 sockets)
Rated current: 86.0 A
Protection class: IP 54
Technical Design:
Refrigeration unit:
water-cooled, low noise, semi-hermetic,
stepless power adjustment through electronic
monitoring and control system,
environmentally friendly refrigerant R 23 / R 404 A
Notes
Inspection possible by appointment (46325 Borken)
Shipping by freight forwarder possible – costs & organization on request
Scope of supply: (See image)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Pošaljite upit
Telefon & Faks
+49 2861 ... oglasi
Ovi oglasi bi vas također mogli zanimati.
Uspješno
Vaša poruka je poslana.
Mali oglas
Borken
1.194 km
CTS klimatska ispitna komora CW-60/5,5, temperaturni raspon od -60°C do +100°C, zapremina 5500 litar
CTSKlimakammer CW -60/5,5
CTSKlimakammer CW -60/5,5
Vaš oglas je uspješno izbrisan
Došlo je do greške