Analizator izgaranja ECOM J2KN ExpertEcom
J2KN Expert
Analizator izgaranja ECOM J2KN Expert
Ecom
J2KN Expert
VB plus PDV
2.900 €
Godina proizvodnje
2024
Stanje
Polovno
(potpuno funkcionalan)
Lokacija
Saint-Projet 

Osnovni podaci
- Naziv mašine:
- Analizator izgaranja ECOM J2KN Expert
- Proizvođač:
- Ecom
- Model:
- J2KN Expert
- Broj mašine:
- J2KN-14043
- Godina proizvodnje:
- 2024
- Stanje:
- vrlo dobro (rabljeno)
- Funkcionalnost:
- potpuno funkcionalan
Cijena i lokacija
VB plus PDV
2.900 €
- Lokacija:
- 371 Chemin des Clauzes, 82160 Saint-Projet, France

Pozovite
Tehnički detalji
Dokumentacija i certifikacija
Dokumentacija / priručnik
Detalji ponude
- ID oglasa:
- A22705427
- Ažuriranje:
- posljednji put 28.09.2026
Opis
The analyzer is in very good condition and has not been used since its last certification in 2024.
It comes with a complete package, including numerous accessories and options.
Robust and comprehensive:
The analyzer is housed in its aluminum case, making it compact, easy to carry, robust, and complete. It is equipped with a metal condensation pot with an integrated PELTIER cooler, a dust filter, and automatic condensate drainage via a purge valve. Its aluminum chassis is guaranteed for 10 years. For over 20 years, our customers have praised this type of analyzer!
Easy to use:
The power supply is integrated into the housing. The long-life cells (up to 6 years in normal use) offer fast response times. You can replace the cells yourself.
The ECOM JKNP.expert automatically prints the combustion and emissions analysis report. The report can directly display values in ppm, as well as a second unit, such as mg/m3, referenced to a % of O2.
Expandable:
It can accommodate up to 6 electrochemical cells. At any time, you can add measurements for SO2, CO%, etc.
Pedpfx Aszy Skxsaxjgt
For long-term measurements:
The ECOM JKNP.expert is designed to measure medium and large-capacity boilers equipped with modern, modulating burners for extended periods.
Control unit for added convenience:
The control unit displays the measurements transmitted to it by the analyzer via radio waves. The measurements remain fast, and the display can be magnetically attached near the burner.
CO cell purging with a second pump:
In case of poor combustion during the adjustment of a fuel or gas burner, a purging pump automatically limits the over-concentration of CO in the CO cell. The purging system is automatic (starting from 4000 ppm, adjustable) or manual.
Work without interruption, in complete peace of mind.
Oglas je automatski preveden. Moguće su greške u prijevodu.
It comes with a complete package, including numerous accessories and options.
Robust and comprehensive:
The analyzer is housed in its aluminum case, making it compact, easy to carry, robust, and complete. It is equipped with a metal condensation pot with an integrated PELTIER cooler, a dust filter, and automatic condensate drainage via a purge valve. Its aluminum chassis is guaranteed for 10 years. For over 20 years, our customers have praised this type of analyzer!
Easy to use:
The power supply is integrated into the housing. The long-life cells (up to 6 years in normal use) offer fast response times. You can replace the cells yourself.
The ECOM JKNP.expert automatically prints the combustion and emissions analysis report. The report can directly display values in ppm, as well as a second unit, such as mg/m3, referenced to a % of O2.
Expandable:
It can accommodate up to 6 electrochemical cells. At any time, you can add measurements for SO2, CO%, etc.
Pedpfx Aszy Skxsaxjgt
For long-term measurements:
The ECOM JKNP.expert is designed to measure medium and large-capacity boilers equipped with modern, modulating burners for extended periods.
Control unit for added convenience:
The control unit displays the measurements transmitted to it by the analyzer via radio waves. The measurements remain fast, and the display can be magnetically attached near the burner.
CO cell purging with a second pump:
In case of poor combustion during the adjustment of a fuel or gas burner, a purging pump automatically limits the over-concentration of CO in the CO cell. The purging system is automatic (starting from 4000 ppm, adjustable) or manual.
Work without interruption, in complete peace of mind.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Dobavljač
Napomena: Registrujte se besplatno ili prijavite, za pristup svim informacijama.
Registriran od: 2026
5 Oglasi online
Pošaljite upit
Telefon & Faks
+33 6 87 ... oglasi
Vaš oglas je uspješno izbrisan
Došlo je do greške



























