GBS Test Pulse Rev. 3 Pulse Generator for Long-Term Insulation Tests
The test pulse design is designed for long-term insulation tests on test objects with capacitances up to 6 nF.
Converter for High-Voltage Test Transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation of the sine wave from 16-24 kHz via full bridge.
· Converter voltage adjustable from 0-600 V, Imax=2.6 A, maximum power 1.3 kW
· Pulse current limit 110 A (cut-off threshold)
Pulse Transformer Control
· Control via full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limit 100 A (cut-off threshold)
Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductors (150 μH, 300 μH) to adjust the pulse width and rise time to the load capacitance and voltage.
· Pulse repetition frequency (0.1 – 2.5 kHz), adjustable.
· Polarity: Adjustable positive, negative, or alternating depending on the polarity of the sine signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-way cascade circuit.
· Total transformation ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
Maximum output voltage 15 kV with possible load capacitances of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· 1:1000 parallel voltage divider.
· Overvoltage limitation at approx. 20-23 kV through parallel spark gaps.
· Thermistor for overtemperature detection in the first transformer stage.
· Ground-side current measurement socket 100 mV/A.
Breakdown detection, test
· If the maximum bridge currents for the transformer controls or
if the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
Hfedpfxju Egz Rs Adveb
· The device has a resettable operating hours counter to determine the test time.
Manufacturer's price approx. €59,500
Find more items - new and used - in our shop!
International shipping costs on request!
The test pulse design is designed for long-term insulation tests on test objects with capacitances up to 6 nF.
Converter for High-Voltage Test Transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation of the sine wave from 16-24 kHz via full bridge.
· Converter voltage adjustable from 0-600 V, Imax=2.6 A, maximum power 1.3 kW
· Pulse current limit 110 A (cut-off threshold)
Pulse Transformer Control
· Control via full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limit 100 A (cut-off threshold)
Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductors (150 μH, 300 μH) to adjust the pulse width and rise time to the load capacitance and voltage.
· Pulse repetition frequency (0.1 – 2.5 kHz), adjustable.
· Polarity: Adjustable positive, negative, or alternating depending on the polarity of the sine signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-way cascade circuit.
· Total transformation ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
Maximum output voltage 15 kV with possible load capacitances of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· 1:1000 parallel voltage divider.
· Overvoltage limitation at approx. 20-23 kV through parallel spark gaps.
· Thermistor for overtemperature detection in the first transformer stage.
· Ground-side current measurement socket 100 mV/A.
Breakdown detection, test
· If the maximum bridge currents for the transformer controls or
if the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
Hfedpfxju Egz Rs Adveb
· The device has a resettable operating hours counter to determine the test time.
Manufacturer's price approx. €59,500
Find more items - new and used - in our shop!
International shipping costs on request!
Dobavljač
Napomena: Registrujte se besplatno ili prijavite, za pristup svim informacijama.
Registriran od: 2008
Pošaljite upit
Telefon & Faks
+49 2862 ... oglasi
Ovi oglasi bi vas također mogli zanimati.
Mali oglas
Kolbuszowa
771 km
Mašina za obradu plastike
Koltex Plastic Recycling SystemsXR 8
Koltex Plastic Recycling SystemsXR 8
Mali oglas
Düngenheim
1.064 km
Električna žičana dizalica 5t, brza
Abus KransystemeGM2000.5000 H-322.41.9000.3E 130.20
Abus KransystemeGM2000.5000 H-322.41.9000.3E 130.20
Mali oglas
Soerendonk
1.222 km
Mjenjač / Mjenjač
Flender / SiemensK2S-2,5
Flender / SiemensK2S-2,5
Mali oglas
Wiefelstede
1.253 km
Stege za klupu 150 mm
Heuer FrontSpannweite 235 mm
Heuer FrontSpannweite 235 mm
Mali oglas
Njemačka
972 km
Portalni kran od 35 tona Vollert (2010.)
Vollert
Vollert
Mali oglas
Tönisvorst
1.175 km
Okvir 28427
mitlaufendSPH 150 mm
mitlaufendSPH 150 mm
Vaš oglas je uspješno izbrisan
Došlo je do greške