Komora za ispitivanje temperature, zapremine 680 litaraHeraeus Vötsch
VLM 3068/S -30 °C bis +125 °C
Komora za ispitivanje temperature, zapremine 680 litara
Heraeus Vötsch
VLM 3068/S -30 °C bis +125 °C
Godina proizvodnje
2010
Stanje
Polovno
Lokacija
Borken 

Podaci o mašini
Cijena i lokacija
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Pozovite
Detalji ponude
- ID oglasa:
- A22185287
- Referentni broj:
- 23960
- Ažuriranje:
- posljednji put 23.06.2026
Opis
Here, we offer a Heraeus Vötsch temperature testing chamber.
Vötsch temperature testing chamber, test cabinet VLM 3068/S, air-cooled
(top-loading test chambers for construction materials)
Control panel
The control panel is mounted on a console on the temperature testing chamber. All control and operating commands can be initiated by simply touching the function symbols. The operating manual for the control panel is included.
Main switch
The main switch is located at the front of the temperature testing chamber.
Air handling unit
The air handling unit is located in the test chamber and contains the components necessary for temperature control.
In the air handling unit, the air is conditioned (cooled/heated) and circulated through the test chamber by the test chamber fan. The air is drawn in at the center of the side wall and re-enters the test chamber via the air guide plates on the long sides.
Feedthroughs
The temperature testing chamber can optionally be equipped with feedthroughs. These allow cables and testing equipment to be placed in the test chamber.
Feedthrough at the front: 2 x 82 mm diameter, at the rear: 1 x 85 mm diameter
Internal dimensions: width 2000 mm, depth 570 mm, height 600 mm
External dimensions: width 3000 mm, depth 870 mm, height 1060 mm
Technical data:
Data for mechanical load:
max. load with test specimen
Test chamber floor
(evenly distributed over the area) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Gjdpfszgbmisx Ableiw
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Rated voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW, rated current 9 A
Fuse on customer side: 16A, slow-blow
Temperature testing chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement: sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Vötsch temperature testing chamber, test cabinet VLM 3068/S, air-cooled
(top-loading test chambers for construction materials)
Control panel
The control panel is mounted on a console on the temperature testing chamber. All control and operating commands can be initiated by simply touching the function symbols. The operating manual for the control panel is included.
Main switch
The main switch is located at the front of the temperature testing chamber.
Air handling unit
The air handling unit is located in the test chamber and contains the components necessary for temperature control.
In the air handling unit, the air is conditioned (cooled/heated) and circulated through the test chamber by the test chamber fan. The air is drawn in at the center of the side wall and re-enters the test chamber via the air guide plates on the long sides.
Feedthroughs
The temperature testing chamber can optionally be equipped with feedthroughs. These allow cables and testing equipment to be placed in the test chamber.
Feedthrough at the front: 2 x 82 mm diameter, at the rear: 1 x 85 mm diameter
Internal dimensions: width 2000 mm, depth 570 mm, height 600 mm
External dimensions: width 3000 mm, depth 870 mm, height 1060 mm
Technical data:
Data for mechanical load:
max. load with test specimen
Test chamber floor
(evenly distributed over the area) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Gjdpfszgbmisx Ableiw
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Rated voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW, rated current 9 A
Fuse on customer side: 16A, slow-blow
Temperature testing chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement: sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Pošaljite upit
Telefon & Faks
+49 2861 ... oglasi
Vaš oglas je uspješno izbrisan
Došlo je do greške