Memmert ICH 750 chamber from 2022, originally packaged and tested, condition like new, one year warranty on spare parts
Temperature
Set temperature range: -10 to +60 °C
Operating temperature range:
from -10°C to +60°C without humidity
(not suitable for long-term storage at sub-zero temperatures. During continuous operation, glass doors may frost over)
Operating temperature range:
from +10°C to +60°C with humidity and/or light
Temperature setting accuracy: 0.1 °C
Temperature sensors:
2 Pt100 sensors, DIN A class, 4-wire configuration, mutually monitoring and taking over in case of failure
Humidity
Humidity supply:
Distilled water supply from external tank via self-priming pump
Humidification:
Steam generator-based humidification
Humidity:
Active humidification and dehumidification adjustable within the 10–80% rh range with digital relative humidity display – display resolution 0.1%, setpoint accuracy 0.5%
Control Technology
ControlCOCKPIT
TwinDISPLAY. Adaptive, multifunctional digital PID microprocessor controller with two high-resolution TFT color displays.
Adjustable parameters:
temperature (°C or °F), fan speed, relative humidity, program time, time zones, summer/winter time
Language settings:
German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese
Timer:
Digital countdown timer with target time setting, adjustable from 1 minute to 99 days
SetpointWAIT function:
Process time does not begin until the set temperature is reached
Calibration:
Up to three user-defined values for temperature/humidity and two for CO₂
Ventilation
Fan:
Forced air circulation in the working chamber, adjustable from 10–100% in 10% increments
Communication
Documentation:
Program retained in memory in case of power failure
Programming:
AtmoCONTROL software on USB stick for programming, managing, and transferring programs via Ethernet interface or USB port
Safety
Temperature control:
Mechanical temperature limiter TB, protection class 1 in accordance with DIN 12880, which disconnects heating approx. 10 °C above setpoint temperature
Fpsdpjxcgh Rsfx Afuer
Temperature monitoring:
Over- and under-temperature monitor TWW, safety class 3.3, or adjustable temperature limiter TWB, safety class 2, selectable from display
AutoSAFETY:
Integrated over- and under-temperature protection system "ASF", automatically tracks set value within fixed tolerance range, alarm if temperature is exceeded or falls below threshold; in case of over-temperature, heating is shut off, in under-temperature – compressor
Self-diagnostic system:
Integrated fault diagnosis for temperature and humidity monitoring
Alarm:
Visual and acoustic
Heating concept
Air jacket:
Air jacket heating system for gentle, even heating
Heating concept:
No sample drying caused by the cooling unit due to separation of heating jacket from chamber interior
Cooling:
Energy-efficient, CFC-free heating/cooling system, refrigerant R 134A
Defrosting:
High-efficiency, automatic defrost system
Standard equipment
Factory calibration certificate
Standard values: +10°C and +37°C, 60% rh at +30°C
Oglas je automatski preveden. Moguće su greške u prijevodu.
Temperature
Set temperature range: -10 to +60 °C
Operating temperature range:
from -10°C to +60°C without humidity
(not suitable for long-term storage at sub-zero temperatures. During continuous operation, glass doors may frost over)
Operating temperature range:
from +10°C to +60°C with humidity and/or light
Temperature setting accuracy: 0.1 °C
Temperature sensors:
2 Pt100 sensors, DIN A class, 4-wire configuration, mutually monitoring and taking over in case of failure
Humidity
Humidity supply:
Distilled water supply from external tank via self-priming pump
Humidification:
Steam generator-based humidification
Humidity:
Active humidification and dehumidification adjustable within the 10–80% rh range with digital relative humidity display – display resolution 0.1%, setpoint accuracy 0.5%
Control Technology
ControlCOCKPIT
TwinDISPLAY. Adaptive, multifunctional digital PID microprocessor controller with two high-resolution TFT color displays.
Adjustable parameters:
temperature (°C or °F), fan speed, relative humidity, program time, time zones, summer/winter time
Language settings:
German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese
Timer:
Digital countdown timer with target time setting, adjustable from 1 minute to 99 days
SetpointWAIT function:
Process time does not begin until the set temperature is reached
Calibration:
Up to three user-defined values for temperature/humidity and two for CO₂
Ventilation
Fan:
Forced air circulation in the working chamber, adjustable from 10–100% in 10% increments
Communication
Documentation:
Program retained in memory in case of power failure
Programming:
AtmoCONTROL software on USB stick for programming, managing, and transferring programs via Ethernet interface or USB port
Safety
Temperature control:
Mechanical temperature limiter TB, protection class 1 in accordance with DIN 12880, which disconnects heating approx. 10 °C above setpoint temperature
Fpsdpjxcgh Rsfx Afuer
Temperature monitoring:
Over- and under-temperature monitor TWW, safety class 3.3, or adjustable temperature limiter TWB, safety class 2, selectable from display
AutoSAFETY:
Integrated over- and under-temperature protection system "ASF", automatically tracks set value within fixed tolerance range, alarm if temperature is exceeded or falls below threshold; in case of over-temperature, heating is shut off, in under-temperature – compressor
Self-diagnostic system:
Integrated fault diagnosis for temperature and humidity monitoring
Alarm:
Visual and acoustic
Heating concept
Air jacket:
Air jacket heating system for gentle, even heating
Heating concept:
No sample drying caused by the cooling unit due to separation of heating jacket from chamber interior
Cooling:
Energy-efficient, CFC-free heating/cooling system, refrigerant R 134A
Defrosting:
High-efficiency, automatic defrost system
Standard equipment
Factory calibration certificate
Standard values: +10°C and +37°C, 60% rh at +30°C
Oglas je automatski preveden. Moguće su greške u prijevodu.
Dobavljač
Napomena: Registrujte se besplatno ili prijavite, za pristup svim informacijama.