Diferencijalni skenirajući kalorimetar (DSC)Perkin Elmer
DSC 8000, N5340524
Diferencijalni skenirajući kalorimetar (DSC)
Perkin Elmer
DSC 8000, N5340524
EXW fiksna cijena plus PDV
29.750 €
Stanje
Polovno
Lokacija
Dresden 

Slike prikazuju
Prikaži kartu
Podaci o mašini
- Naziv mašine:
- Diferencijalni skenirajući kalorimetar (DSC)
- Proizvođač:
- Perkin Elmer
- Model:
- DSC 8000, N5340524
- Stanje:
- polovno
Cijena i lokacija
EXW fiksna cijena plus PDV
29.750 €
- Lokacija:
- Heilbronner Str. 22, 01189 Dresden, Deutschland

Pozovite
Detalji ponude
- ID oglasa:
- A21283042
- Referentni broj:
- LW43630
- Ažuriranje:
- posljednji put 20.02.2026
Opis
Perkin Elmer Instruments Differential Scanning Calorimeter with Cooling, DSC 8000, N5340524
Model: DSC8000
Type: N5340524
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000, equipped with Intracooler 2. Enables precise heat flow measurements from approx. –70 °C to 750 °C with high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Dual furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Nwedpfxoyluics Afaec
Temperature Performance
Standard temperature range: approx. –180 °C to 750 °C (with suitable cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and fast response due to low-mass furnace design
Excellent baseline stability and temperature accuracy
Gas and Atmosphere Control
Two regulated gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photocalorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power consumption 400 VA
Accessories
Cooling system: PolyScience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
Autosampler with 96 positions
High-pressure DSC cells, UV/photocalorimeter accessories
IEC power connection
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on Item Condition:
Without software/PC
Oglas je automatski preveden. Moguće su greške u prijevodu.
Model: DSC8000
Type: N5340524
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000, equipped with Intracooler 2. Enables precise heat flow measurements from approx. –70 °C to 750 °C with high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Dual furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Nwedpfxoyluics Afaec
Temperature Performance
Standard temperature range: approx. –180 °C to 750 °C (with suitable cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and fast response due to low-mass furnace design
Excellent baseline stability and temperature accuracy
Gas and Atmosphere Control
Two regulated gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photocalorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power consumption 400 VA
Accessories
Cooling system: PolyScience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
Autosampler with 96 positions
High-pressure DSC cells, UV/photocalorimeter accessories
IEC power connection
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on Item Condition:
Without software/PC
Oglas je automatski preveden. Moguće su greške u prijevodu.
Dobavljač
Napomena: Registrujte se besplatno ili prijavite, za pristup svim informacijama.
Registriran od: 2014
Pošaljite upit
Telefon & Faks
+49 351 8... oglasi
Vaš oglas je uspješno izbrisan
Došlo je do greške




























