Ćelija za simulaciju klimeTIRA
KB 127 TCZ 4022 S -2K -40 bis +140°C
Ćelija za simulaciju klime
TIRA
KB 127 TCZ 4022 S -2K -40 bis +140°C
Stanje
Polovno
Lokacija
Borken 

Slike prikazuju
Prikaži kartu
Podaci o mašini
Cijena i lokacija
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Pozovite
Detalji ponude
- ID oglasa:
- A18478886
- Referentni broj:
- 23515
- Ažuriranje:
- posljednji put 12.03.2026
Opis
TIRA
Type: TCZ 4022 S -2K
Description: Air-cooled climate simulation chamber
System Structure:
The unit consists of the following main assemblies:
- Walk-in, insulated chamber
- Air handling room
- Humidification system
- Machinery room
- Control cabinet
Technical Data:
Performance Range for Temperature Testing:
- Temperature range: -40...+140°C
- Temperature stability, in supply air (temporal): ≤ ±0.5°C (without thermal test chamber load, according to DIN 50011 T13 / EN 60068)
- Temperature stability, in supply air (spatial): ≤ ±1.0°C (without thermal test chamber load, according to DIN 50011 / EN 60068)
- Heating rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
- Cooling rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
Performance Range for Climate Testing:
- Temperature range: +10...+90°C
- Humidity working range: 10...approx. 95% RH (without thermal test chamber load)
- Dew point temperature range: +5...+89°C (without thermal test chamber load)
- Humidity stability (in supply air, temporal): ≤ ±2.5% RH, measured in supply air
Performance Range for Climate Testing with Heat Compensation:
- Temperature range: +15...+80°C
- Humidity: 15...approx. 80% RH (without thermal test chamber load; with max. 16 kW heat compensation)
- Dew point temperature range: +10...+74°C (without thermal test chamber load)
Dimensions:
- Test chamber (WxDxH): approx. 2260 x 4648 x 2260 mm
- External dimensions (WxDxH): approx. 2660 x 6460 x 2800 mm
- Clear door passage test chamber door (WxH): 2260 x 2260 mm
- Climate module KB 127 (WxDxH): 1700 x 800 x 1400 mm
- Control cabinet (WxDxH): 800 x 500 x 2000 mm
Design:
- Airflow: Supply air via perforated plate at the rear wall, ceiling area; exhaust air via perforated plate at the rear wall, floor area
- Temperature control: Direct cooling via evaporation of refrigerant in a finned heat exchanger; heating via electric resistance heater
- Dehumidification: Direct dehumidification via refrigerant evaporation in a heat exchanger
Ljdevx S Hhjpfx Ag Iehd
- Interior lining: Stainless steel
- Exterior cladding: Galvanized, plastic-coated steel sheet
- Floor: Stainless steel, floor load 15,000 N/m²
- Wheel load (contact area ≥4 cm²): 1,500 N/wheel
- Door: Double-leaf, stainless steel, externally coated with viewing window (WxH): 1000 x 1000 mm
- Test area lighting: 4 spotlights, 500 W each
- Insulation: Dual-layer insulation, 80 mm PUR foam, 120 mm mineral wool
- Refrigeration unit (1 pc): Bitzer 6G-30.2Y
- Refrigerant: R449A
- Refrigeration oil: SEZ 32
- Steam humidifier (1 pc): EDB 40
Color scheme:
- Chamber RAL 9010, white
- Door RAL 9010, white
- Machine unit RAL 7032, pebble grey
- Control cabinet RAL 7032, pebble grey
Weights:
- Total system: approx. 4,900 kg
- Machine set KB 127: approx. 750 kg
- Control cabinet: approx. 120 kg
- Humidification unit: approx. 64 kg
Connections:
- Rated voltage: 400 V +6%/-10%, 3/PE N, 50Hz
- Rated power: 95 kW
- Rated current: 150 A
Oglas je automatski preveden. Moguće su greške u prijevodu.
Type: TCZ 4022 S -2K
Description: Air-cooled climate simulation chamber
System Structure:
The unit consists of the following main assemblies:
- Walk-in, insulated chamber
- Air handling room
- Humidification system
- Machinery room
- Control cabinet
Technical Data:
Performance Range for Temperature Testing:
- Temperature range: -40...+140°C
- Temperature stability, in supply air (temporal): ≤ ±0.5°C (without thermal test chamber load, according to DIN 50011 T13 / EN 60068)
- Temperature stability, in supply air (spatial): ≤ ±1.0°C (without thermal test chamber load, according to DIN 50011 / EN 60068)
- Heating rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
- Cooling rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
Performance Range for Climate Testing:
- Temperature range: +10...+90°C
- Humidity working range: 10...approx. 95% RH (without thermal test chamber load)
- Dew point temperature range: +5...+89°C (without thermal test chamber load)
- Humidity stability (in supply air, temporal): ≤ ±2.5% RH, measured in supply air
Performance Range for Climate Testing with Heat Compensation:
- Temperature range: +15...+80°C
- Humidity: 15...approx. 80% RH (without thermal test chamber load; with max. 16 kW heat compensation)
- Dew point temperature range: +10...+74°C (without thermal test chamber load)
Dimensions:
- Test chamber (WxDxH): approx. 2260 x 4648 x 2260 mm
- External dimensions (WxDxH): approx. 2660 x 6460 x 2800 mm
- Clear door passage test chamber door (WxH): 2260 x 2260 mm
- Climate module KB 127 (WxDxH): 1700 x 800 x 1400 mm
- Control cabinet (WxDxH): 800 x 500 x 2000 mm
Design:
- Airflow: Supply air via perforated plate at the rear wall, ceiling area; exhaust air via perforated plate at the rear wall, floor area
- Temperature control: Direct cooling via evaporation of refrigerant in a finned heat exchanger; heating via electric resistance heater
- Dehumidification: Direct dehumidification via refrigerant evaporation in a heat exchanger
Ljdevx S Hhjpfx Ag Iehd
- Interior lining: Stainless steel
- Exterior cladding: Galvanized, plastic-coated steel sheet
- Floor: Stainless steel, floor load 15,000 N/m²
- Wheel load (contact area ≥4 cm²): 1,500 N/wheel
- Door: Double-leaf, stainless steel, externally coated with viewing window (WxH): 1000 x 1000 mm
- Test area lighting: 4 spotlights, 500 W each
- Insulation: Dual-layer insulation, 80 mm PUR foam, 120 mm mineral wool
- Refrigeration unit (1 pc): Bitzer 6G-30.2Y
- Refrigerant: R449A
- Refrigeration oil: SEZ 32
- Steam humidifier (1 pc): EDB 40
Color scheme:
- Chamber RAL 9010, white
- Door RAL 9010, white
- Machine unit RAL 7032, pebble grey
- Control cabinet RAL 7032, pebble grey
Weights:
- Total system: approx. 4,900 kg
- Machine set KB 127: approx. 750 kg
- Control cabinet: approx. 120 kg
- Humidification unit: approx. 64 kg
Connections:
- Rated voltage: 400 V +6%/-10%, 3/PE N, 50Hz
- Rated power: 95 kW
- Rated current: 150 A
Oglas je automatski preveden. Moguće su greške u prijevodu.
Pošaljite upit
Telefon & Faks
+49 2861 ... oglasi
Ovi oglasi bi vas također mogli zanimati.
Mali oglas
Pfalzgrafenweiler
869 km
Laboratorijska presa
JoosLAP-M 30
JoosLAP-M 30
Mali oglas
Olsztyn
1.117 km
Laboratorijska oprema - Set
Shimadzu, Wyposażenie laboratorium
Shimadzu, Wyposażenie laboratorium
Mali oglas
Matelica (MC)
384 km
Glodalice - A portale
PARPASDIAMOND LINEAR30
PARPASDIAMOND LINEAR30
Mali oglas
Skarżysko-Kamienna
838 km
Električna peć za polimerizaciju
Romer PolandSL - 2020
Romer PolandSL - 2020
Mali oglas
Enschede
1.222 km
Mašine za lasersko rezanje cijevi
Bodor K2
Bodor K2
Mali oglas
Wuppertal
1.135 km
Spotting press
HESSMERT160 EST
HESSMERT160 EST
Mali oglas
Zuchwil
869 km
Retortna peć za termičku obradu
MUT360/400-1150
MUT360/400-1150
Mali oglas
Gelnhausen
951 km
Pfeiffer vakuum Okta 6000
Pfeiffer VacuumOkta 6000
Pfeiffer VacuumOkta 6000
Mali oglas
Möckmühl
874 km
Mašina za termoformiranje
IlligUA 200 G Solo/BE
IlligUA 200 G Solo/BE
Mali oglas
Möckmühl
874 km
Mašina za termoformiranje
IlligUA 155 G Solo/ BE
IlligUA 155 G Solo/ BE
Vaš oglas je uspješno izbrisan
Došlo je do greške