Weiss komora za ispitivanje emisija WT 5,1'/ + 18-45 Mini-SHED za mjerenje dnevnih (diurnal) gubitakWeiss
Emissionsprüfkammer
Weiss komora za ispitivanje emisija WT 5,1'/ + 18-45 Mini-SHED za mjerenje dnevnih (diurnal) gubitak
Weiss
Emissionsprüfkammer
VB plus PDV
130.000 €
Stanje
Polovno
Lokacija
Borken 

Osnovni podaci
- Naziv mašine:
- Weiss komora za ispitivanje emisija WT 5,1'/ + 18-45 Mini-SHED za mjerenje dnevnih (diurnal) gubitak
- Proizvođač:
- Weiss
- Model:
- Emissionsprüfkammer
- Stanje:
- polovno
Cijena i lokacija
VB plus PDV
130.000 €
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Pozovite
Detalji ponude
- ID oglasa:
- A22148392
- Referentni broj:
- 23531
- Ažuriranje:
- posljednji put 15.10.2026
Opis
Weiss
Type: WT 5.1'/
Mini-SHED for diurnal loss measurements
Test chamber dimensions: Width 1600 mm x Depth 2140 mm x Height 2150 (usable 1600) mm
Housing dimensions: Width 1760 mm x Depth 3100 mm x Height 2790 mm
Maximum floor load: 250 kg
Operating temperature range: +18 °C ... +45 °C (at higher temperatures, SHED operation is only possible without a Tedlar bag)
Temperature range: +18 °C ... +45 °C
Temperature stability: ≤ ±1 K (over time)
Temperature change rate (heating and cooling): approx. 0.5 K/min, without test specimen
Channel connection (air inlet and outlet): ∅ 80 mm, in the rear wall of the chamber
Shut-off valve, gas-tight (air inlet and outlet): ∅ 80 mm, gas-tight, pneumatic operation. Delivery scope: Connection flange of the shut-off valve
Cooling water consumption: approx. 0.8 m3/h
Voltage: 230/400 V; 3 phases + N + PE; 50 Hz
Rated power: 4.1 kW Rated current: 14.0 A
Weight: approx. 2500 kg
Type: WT 5.1'/
Condition: used
Sale from current location
Scope of delivery: (Only the Weiss emissions test chamber WT 5.1' + Mini-SHED)
(Changes and errors in the technical data are subject to change!)
Iodpfszd Slkex Akgebc
We will be happy to answer any further questions you may have by telephone.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Type: WT 5.1'/
Mini-SHED for diurnal loss measurements
Test chamber dimensions: Width 1600 mm x Depth 2140 mm x Height 2150 (usable 1600) mm
Housing dimensions: Width 1760 mm x Depth 3100 mm x Height 2790 mm
Maximum floor load: 250 kg
Operating temperature range: +18 °C ... +45 °C (at higher temperatures, SHED operation is only possible without a Tedlar bag)
Temperature range: +18 °C ... +45 °C
Temperature stability: ≤ ±1 K (over time)
Temperature change rate (heating and cooling): approx. 0.5 K/min, without test specimen
Channel connection (air inlet and outlet): ∅ 80 mm, in the rear wall of the chamber
Shut-off valve, gas-tight (air inlet and outlet): ∅ 80 mm, gas-tight, pneumatic operation. Delivery scope: Connection flange of the shut-off valve
Cooling water consumption: approx. 0.8 m3/h
Voltage: 230/400 V; 3 phases + N + PE; 50 Hz
Rated power: 4.1 kW Rated current: 14.0 A
Weight: approx. 2500 kg
Type: WT 5.1'/
Condition: used
Sale from current location
Scope of delivery: (Only the Weiss emissions test chamber WT 5.1' + Mini-SHED)
(Changes and errors in the technical data are subject to change!)
Iodpfszd Slkex Akgebc
We will be happy to answer any further questions you may have by telephone.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Pošaljite upit
Telefon & Faks
+49 2861 ... oglasi
Vaš oglas je uspješno izbrisan
Došlo je do greške