Klimatska testna komora 800 L od -55°C do +180°CWeiss
ClimeEvent C/800/55a/25/S 25K/min
Klimatska testna komora 800 L od -55°C do +180°C
Weiss
ClimeEvent C/800/55a/25/S 25K/min
Godina proizvodnje
2020
Stanje
Polovno
Lokacija
Borken 

Slike prikazuju
Prikaži kartu
Podaci o mašini
- Naziv mašine:
- Klimatska testna komora 800 L od -55°C do +180°C
- Proizvođač:
- Weiss
- Godina proizvodnje:
- 2020
- Stanje:
- vrlo dobro (rabljeno)
Cijena i lokacija
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Pozovite
Detalji ponude
- ID oglasa:
- A19821050
- Referentni broj:
- 24761
- Ažuriranje:
- posljednji put 22.08.2025
Opis
Weiss
Type: C/800/55a/25/S
Year of manufacture: 2020
Weiss ClimeEvent Climate Test Chamber, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load capacity: designed for a maximum load of 250 kg
Specifications for temperature testing:
Temperature range: -55 to +180°C
Temporal temperature fluctuation at chamber center: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (down to -45°C)
Heating compensation: max. 8000 W
Specifications for climate testing:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Climate performance data (excerpt)
Humidity range: 10 to 98% relative humidity (RH)
Humidity deviation (temporal):
At chamber center, in steady-state condition, depending on climatic setting:
±1 to ±3% RH
Temperature deviation (temporal):
At chamber center, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20% RH):
±0.5 to ±1 K
Operational data:
LED strip: 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10%, 50 Hz
Rated power: 53 kW
Rated current: 87 A
Hfedpfew R Rt Iex Afujr
Refrigerant: WT69-R449A
Chamber is equipped with Greenmode
Weight: approx. 2050 kg
Buyer Safety Information!
The following steps are performed on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful testing, chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)
For further questions, we are happy to answer your call.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Type: C/800/55a/25/S
Year of manufacture: 2020
Weiss ClimeEvent Climate Test Chamber, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load capacity: designed for a maximum load of 250 kg
Specifications for temperature testing:
Temperature range: -55 to +180°C
Temporal temperature fluctuation at chamber center: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (down to -45°C)
Heating compensation: max. 8000 W
Specifications for climate testing:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Climate performance data (excerpt)
Humidity range: 10 to 98% relative humidity (RH)
Humidity deviation (temporal):
At chamber center, in steady-state condition, depending on climatic setting:
±1 to ±3% RH
Temperature deviation (temporal):
At chamber center, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20% RH):
±0.5 to ±1 K
Operational data:
LED strip: 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10%, 50 Hz
Rated power: 53 kW
Rated current: 87 A
Hfedpfew R Rt Iex Afujr
Refrigerant: WT69-R449A
Chamber is equipped with Greenmode
Weight: approx. 2050 kg
Buyer Safety Information!
The following steps are performed on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful testing, chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)
For further questions, we are happy to answer your call.
Oglas je automatski preveden. Moguće su greške u prijevodu.
Dobavljač
Napomena: Registrujte se besplatno ili prijavite, za pristup svim informacijama.
Registriran od: 2012
Pošaljite upit
Telefon & Faks
+49 2861 ... oglasi
Ovi oglasi bi vas također mogli zanimati.
Mali oglas
Rimini
409 km
Mašina za ispitivanje pritiska / zatezanja
ZwickRoell GmbHZ005TN
ZwickRoell GmbHZ005TN
Mali oglas
Borken
1.195 km
Univerzalni ispitni sistem za zatezanje i pritisak
Instron 34TM-50 50kN Serie 340034TM-50 Zug und Druckmaschine
Instron 34TM-50 50kN Serie 340034TM-50 Zug und Druckmaschine
Mali oglas
Sonsbeck
1.200 km
Mašina za ispitivanje zatezanja univerzalna mašina za ispitivanje
Hegewald & PeschkeH5TMCI
Hegewald & PeschkeH5TMCI
Mali oglas
Sonsbeck
1.200 km
Mašina za ispitivanje zatezanja univerzalna mašina za ispitivanje
Richard Hess MBV GmbHH3000-H5000TM mit Langwegextensometer
Richard Hess MBV GmbHH3000-H5000TM mit Langwegextensometer
Mali oglas
Borken
1.194 km
Klimatska komora
VötschVC³ 4060
VötschVC³ 4060
Mali oglas
Wiesbaden
993 km
Rockwell tvrdoće ispitivač
REICHERTERBriro-Pedal
REICHERTERBriro-Pedal
Mali oglas
Njemačka
972 km
Mašina za bušenje
TRUMPF TC5000-1300 . Year 2003.Low working hours . 30000 Hours
TRUMPF TC5000-1300 . Year 2003.Low working hours . 30000 Hours
Mali oglas
Borken
1.194 km
Ormarić za ispitivanje korozije za slani sprej
VLMCC 1000-FL HL V.745.672.120
VLMCC 1000-FL HL V.745.672.120
Mali oglas
Borken
1.194 km
Komora za ispitivanje korozije
VLMSAL 400 V.713.062.000
VLMSAL 400 V.713.062.000
Mali oglas
Borken
1.194 km
Komora za klimatski test sa vlažnošću
VötschVC³ 4100 990 Liter -42°C bis +180°C
VötschVC³ 4100 990 Liter -42°C bis +180°C
Vaš oglas je uspješno izbrisan
Došlo je do greške